Users Guide

Table 6. Proactive HA events (continued)
Event name Description Severity
Integrated Dual SD Module
Redundancy Lost
Integrated Dual SD Module redundancy is lost Critical
Chassis events
Fan Information Fan information Info
Fan Warning Fan warning Warning
Fan Failure Fan failure Critical
Power Supply Normal The power supply returns to normal Info
Power Supply Warning The power supply detects a warning Warning
Power Supply Failure The power supply detects a failure Critical
Redundancy Information Redundancy information Info
Redundancy Degraded Redundancy is degraded Warning
Redundancy Lost Redundancy is lost Critical
Related tasks
Hardware component redundancy healthProactive HA on page 80
Configure Proactive HA for Rack and Tower servers on page 82
Enable Proactive HA on clusters on page 83
Related information
Override severity of health update notification on page 83
Configure Proactive HA for Rack and Tower servers
Ensure that all hosts are configured for redundancy of all the three supported redundant components (power supply, fans, and
IDSDM).
1. Create a host credential profile and associate hosts to a host credential profile. See Create host credential profile on page
35.
2. Verify that hosts inventory is completed successfully. See View host inventory job on page 74.
3. Verify that the SNMP Trap destination in iDRAC is set as the OMIVV appliance IP address.
NOTE: Ensure to confirm the availability of a host for a Proactive HA cluster from the logs data.
4. Enable Proactive HA on a cluster. See Enabling Proactive HA on a cluster.
Related references
Proactive HA events on page 81
Related information
Override severity of health update notification on page 83
Configure Proactive HA for Modular servers
Before configuring Proactive HA for the Modular servers, ensure that the following conditions are met:
All hosts are properly configured for redundancy of all the three supported redundant components (power supply, fans, and
IDSDM).
Hosts and chassis inventory is completed successfully.
82