To view and manage hosts in OMIVV, each host must meet certain criteria. If the hosts do not meet the compliance criteria,
OMIVV will not manage and monitor them. OMIVV displays details about the noncompliance host, and enables you to fix the
noncompliance, where applicable.
The host is non-compliant if:
● The host is not associated to a Host Credential Profile.
● The Collect System Inventory on Reboot (CSIOR) feature is disabled or has not been run, which requires a manual reboot.
NOTE: The CSIOR status is not determined when hosts are managed using a chassis.
● The SNMP trap destination of the host is not configured to the OMIVV appliance IP address. The failure in SNMP trap
destination setting might be when iDRAC or host credentials that are provided in host credential a profile is invalid. Or, there
are no free slots in iDRAC, or iDRAC Lockdown Mode is turned on—only in 14G and later hosts.
● OMIVV fails to enable the WBEM service on hosts running ESXi 6.5 and later.
● The iDRAC firmware version is lower than 2.50.50.50. The iDRAC version 2.50.50.50 or higher is required only to use the
system profile feature.
● iDRAC license is not compatible (iDRAC Express is the minimum requirement). The servers without a compatible iDRAC
license cannot be used for monitoring and updating the firmware.
CAUTION:
Even if non-compliant, the hosts in the Lockdown mode are not displayed in the compliance tests.
Ensure to manually check the compliance level. A message is displayed when manually checked. Ignore the
message. They do not display because their compliance status cannot be determined. Ensure to check the
compliance of these systems manually. In such a scenario, a warning message is displayed.
On the Management Compliance page, you can perform the following tasks:
● Fix compliance. For more information, see Fix a non-compliant host on page 67.
● Run inventory. The run inventory job link is active if the iDRAC status is non-compliant or Unknown for any one of the
hosts that are associated to a host credential profile.
● Renew iDRAC License. For information, see Fix iDRAC license compliance on page 68.
● Add OEM hosts. For more information about adding OEM hosts, see Add OEM hosts on page 68.
Related tasks
View non-compliant hosts on page 66
Fix a non-compliant host on page 67
View non-compliant hosts
1. On the OMIVV home page, click Compliance & Deployment > Management Compliance.
A table displays all the non-compliant hosts along with the following information:
● Host—The FQDN or IP address of the host
● Model—The model name of the server
● Credential Profile—The host credential profile name
● CSIOR Status—The CSIOR status (ON or OFF). The CSIOR status shows Undetermined for hosts that are managed
using chassis,
● SNMP Trap Status—The SNMP Trap Status (Configured or Not Configured).
● Hypervisor—The hypervisor name and version
9