Users Guide

In vCenter, recent tasks pane does not show the details column for
some OMIVV task notifications
Resolution: To see the task notifications, in vCenter, go to Task Console of vCenter.
Version Affected: 5.0
Unable to see the failure details in OMIVV logs for failed MX
chassis firmware update job
Resolution: Log in to OME-Modular and check the firmware update job status.
If the status shows Success in OME-Modular, OMIVV updates firmware details in the next chassis inventory.
Version Affected: 5.0
Host firmware update fails, if a canceled firmware update job of
related chassis is present
If you cancel the firmware update job of a PowerEdge MX chassis, subsequent host firmware update job for hosts present in the
same chassis is blocked.
Resolution: Purge the canceled chassis firmware update job to release the lock on the related hosts.
On the configuration preview page of the deployment wizard, an
error message is displayed
If you clear the target server after performing the configuration preview operation, an error message is displayedYou must
select server for deployment.
Resolution: Select the target on the configuration preview page to complete the wizard. Selection that is done on this page does
not override the target that is selected on the Select Server (s) page.
Version Affected: 5.0
Bare-metal deployment issues
This section deals with issues found during the deployment process.
Auto discovery and handshake prerequisites
Prior to running auto discovery and handshake, ensure that iDRAC and Lifecycle Controller firmware and BIOS versions meet
the minimum recommendations.
CSIOR must have run at least once on the system or iDRAC.
Hardware configuration failure
Before initiating a deployment task, ensure that the system has completed CSIOR and is not in the process of rebooting.
BIOS configuration should be run in clone mode so that the reference server is an identical system.
Some controllers do not allow creation of a RAID 0 array with one drive. This feature is supported only on high-end
controllers, and the application of such a hardware profile can cause failures.
Enabling auto discovery on newly purchased system
The auto discovery feature of a host system is not enabled by default; instead, enablement must be requested at the time of
purchase. If auto discovery enablement is requested at the time of purchase, DHCP is enabled on the iDRAC and admin
accounts are disabled. It is not necessary to configure a static IP address for the iDRAC. It gets one from a DHCP server on the
Frequently Asked Questions-FAQ
151