Users Guide
Table 25. Virtualization events(continued)
Event name Description Severity Recommended action
NOTE: For all Proactive HA enabled hosts that are part of a cluster, the following virtualization events are mapped to
the Proactive HA events; except events, "The fans are not redundant" and "The power supplies are not redundant" are
not mapped.
The fans are redundant None Info No action
Fan redundancy is lost One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans
Critical Remove and reinstall failed fans
or install additional fans
Fan redundancy is degraded One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans.
Warning Remove and reinstall failed fans
or install additional fans
The fans are not redundant One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans
Info Remove and reinstall failed fans
or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans
Critical Remove and reinstall failed fans
or install additional fans
The power supplies are
redundant
None Info No action
Power supply redundancy is lost The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
previously operating in a power
redundant mode
Critical Check the event log for power
supply failures. Review system
configuration and power
consumption
Power supply redundancy is
degraded
The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
previously operating in a power
redundant mode
Warning Check the event log for power
supply failures. Review system
configuration and power
consumption
The power supplies are not
redundant
The current power supply
configuration does not meet the
platform requirements to enable
redundancy. If a power supply
fails the system may shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for failures
The power supplies are not
redundant. Insufficient
resources to maintain normal
operations
The system may power down or
operate in a performance
degraded state
Critical Check the event log for power
supply failures. Review system
configuration and power
consumption and upgrade or
install power supplies
accordingly
Internal Dual SD Module is
redundant
None Info No action
Events, alarms, and health monitoring 83