Users Guide

Virtualization-related events
The following table contains the virtualization-related critical and warning events, and includes event name, description, severity level, and
recommended action.
The vitalization-related events are displayed in the following format:
Dell-Message ID:<ID number>, Message:<Message Description>.
The chassis events are displayed in the following format:
Dell-Message:<Message description>, Chassis name:<name of the chassis>, Chassis Service Tag:<chassis Service Tag >, Chassis
Location:<chassis location>
Table 25. Virtualization events
Event name Description Severity Recommended action
Dell-Current sensor detected a
warning value
A current sensor in the specified
system exceeded its warning
threshold
Warning No action
Dell-Current sensor detected a
failure value
A current sensor in the specified
system exceeded its failure
threshold
Error Put the system into
maintenance mode
Dell-Current sensor detected a
non-recoverable value
A current sensor in the specified
system detected an error from
which it cannot recover
Error No action
Dell-Redundancy regained Sensor Returned to Normal
Value
Info No action
Dell-Redundancy degraded A redundancy sensor in the
specified system detected that
one of the components of the
redundancy unit has failed but
the unit is still redundant
Warning No action
Dell-Redundancy lost A redundancy sensor in the
specified system detected that
one of the components in the
redundant unit has been
disconnected, has failed, or is
not present
Error Put the system into
maintenance mode
Dell-Power supply returned to
normal
Sensor returned to Normal
Value
Info No action
Dell-Power supply detected a
warning
A power supply sensor reading
in the specified system
exceeded a user definable
warning threshold
Warning No action
Dell-Power supply detected a
failure
A power supply has been
disconnected or has failed
Error Put the system into
maintenance mode
Dell-Power supply sensor
detected a non-recoverable
value
A power supply sensor in the
specified system detected an
error from which it cannot
recover
Error No action
Dell-Memory Device Status
warning
A memory device correction
rate exceeded an acceptable
value
Warning No action
Dell-Memory Device error A memory device correction
rate exceeded an acceptable
value, a memory spare bank
Error Put the system into
maintenance mode
78 Events, alarms, and health monitoring