Release Notes

Resolution/Workaround: Each power supply status is shown correctly as critical.
Issue 29: Health Status is showing as Healthy for chassis while Storage status is Warning.
Description: The overall health information is displayed Healthy on summary page for VRTX chassis that has a storage component as
Warning.
Version affected: VRTX firmware version 2.0
Resolution/Workaround: Storage component health status is shown correctly as Warning.
Issue 30: Blower information is showing as N/A for a chassis when a Blower is removed.
Description: Blower inventory information is displayed as N/A on the Monitor page for VRTX chassis when a Blower is removed from a
slot.
Version affected: 2.0 and later
Resolution/Workaround: You can see the fan inventory before the blower was removed.
Issue 31: File type '.csv' is not be appended to the file, if the file name is anything other than "Export List".
Description: When we export any of the grid details from any OMIVVC pages (from IE9), the default File Name "ExportList" is shown.
If saved as is, it will be saved as "ExportList.csv". If the file name is changed to anything other than "Export List", the file will be saved
without any extension.
Opening the file will show all details in comma separated value format. Issue is just to append.
Version affected: M1000e firmware version 5.0
Resolution/Workaround:
1. Login to web client from IE 9, and export any grid value from pages like HW profile, Hypervisor profile, Host - firmware inventory.
2. While saving, change the file name from ExportList to something else, say ExportList123.
3. Save the file with the file extension (in case the default name is changed.)
Issue 32: I see a web communication error in the vCenter web client after changing the DNS settings in OpenManage Integration for
VMware vCenter?
Description: If you see any kind of web communication error in the vCenter web client while doing any OpenManage Integration for
VMWare vCenter related tasks after changing the DNS settings, clear the browser cache or logout and login from the web client.
Version affected: 2.x and later
Resolution/Workaround: Clear the browser cache or log out and log in from the web client.
Issue 33: OMIVV RPM Upgrade fails when Proxy is configured with Domain user authentication
Description: If OMIVV appliance is configured with proxy to reach the internet and proxy is authenticated using NTLM authentication,
then the RPM update will fail due to the issues in the underlying yum tool.
Version Affected: OMIVV 4.0 and above
Resolution/Workaround: Do Backup and Restore to update the OMIVV appliance.
Issue 34: Sometimes OMIVV Inventory, Driver Update and Drift detection jobs for vSAN clusters runs for long time and times out.
Description: If OMIVV appliance is configured to manage vSAN clusters, then sometimes the inventory and firmware update (if driver
included) and drift detection jobs runs for long time and eventually fails after time out. This is because the OMIVV appliance fails to
retrieve the thumbprint information from the registered vCenters in the last reboot. This thumbprint information is used for collecting
driver inventory.
Version Affected: OMIVV 4.2
Resolution: Keep the vCenters server instances up and reboot the OMIVV alliance.
Issue 35: Unable to apply System Profile that has PCIe card in the FX chassis.
Description: The OS deployment fails on a target server if the source server has PCIe card information when using an FX chassis. The
System profiles on the source server has different fc.chassislot ID than the one on the target server. OMIVV tries to deploy
the same fc.chassislot ID on the target server but fails. The System profiles searches for exact instance( FQDD) while applying
the profile, which works successfully on rack servers (identical), but may have few restrictions in modular servers. For example, in
FC640, the System profiles created from one modular server cannot applied on other modular servers in the same FX chassis because
of NIC level restrictions.
Version Affected: OMIVV 4.1 and later
Resolution/Workaround: System profile taken from a FC640 server in slot 1 of a FX2s chassis can only be applied on another FC640
server residing in the slot 1 of another FX2s chassis.
Issue 36: The first inventory (immediately after creating a connection profile) may fail in ESXi 6.5 and later version where the WBEM
enablement is necessary.
OpenManage Integration for VMware vCenter Version 4.3 Release Notes
7