Release Notes
Description: If the iDRAC IP is not retrieved because of non-responsive iDRAC, the inventory fails and host to be associated with the
connection profile is not displayed on the host compliance page.
Version affected: 1.6 and later
Resolution/Workaround: Reset the iDRAC to fix the issue of iDRAC not being responsive, and then rerun the inventory. If the
inventory is able to get the iDRAC IP, then the host will be associated with the correct connection profile.
• Issue 21: Using local host for host name causes issues in identifying the source of SNMP alerts.
Description: Starting with ESXi 5.1, a value of local host for the host name causes issues in identifying the source of SNMP alerts. The
use of local host is not supported and a Fully Qualified Domain Name (FQDN) must be used instead.
Version affected: 1.6 and later
Resolution/Workaround: When deploying an ESXi 5.1 server using DHCP, it is strongly recommended that a combination of a DHCP
reservation based on the selected NIC MAC addresses, and a DNS host entry using the reservation’s IP address must be configured.
You can view the MAC address in Deployment Wizard’s Server Identification page, Network Interface drop-down, and provided to
help identify the network interfaces. The DHCP reservation and DNS entry should be created for the server prior to scheduling the
deployment, and if properly configured, should set the hostname to the value from DNS.
• Issue 22: Deployments failure error message displayed on R210 II machines.
Description: Timeout issue on R210 II systems produces a hypervisor deployments failure error due to failure of BIOS to boot from
attached ISO.
Version affected: 1.5.1 and later
Resolution/Workaround: Manually install hypervisor on the machine.
• Issue 23: Unable to boot to service partition while deploying OS ISO.
Description:Hypervisor deployments are failing on Dell 11th and 12th generation servers with this error displayed on the screen during
POST: "Warning: Unable to boot to Service Partition". There is a BIOS issue to identify the network ISO when there is a local USB CD-
ROM installed on the system and that USB CD- ROM is the only USB mass storage device plugged into the system.
Version affected: 1.5.1 and later
Resolution/Workaround: Remove the local USB CD-ROM (note that not all local CD-ROM would expose this issue), or plug in
additional USB floppy or USB key on the system, or attach the virtual media (virtual floppy and virtual CD) from the iDRAC.
• Issue 24: A firmware update fails with an error message saying that USC is in use and it must be retried after 30 seconds.
Description: During a firmware update, the update fails with the error message: If USC is in use, wait until USC has exited and retry the
action. Otherwise retry after 30 seconds to check if network connectivity caused this error.
Version affected:1.5.1 and later
Resolution/Workaround: To fix this issue, reset iDRAC and wait until iDRAC boots properly and try the firmware update again.
• Issue 25: Events from different vCenter are posted to another vCenter from a shared OpenManage Integration appliance.
Description: This situation can occur when a bare-metal server that was deployed in one vCenter is rediscovered again as bare-metal
server but then selected for a hypervisor deployed in another vCenter. This situation occurs if the host that was already on one of the
registered vCenter was added to another registered vCenter. In this case the host on first vCenter appears as disconnected.
Version affected: All
Resolution/Workaround: Remove the host from the first vCenter where it is now showing as disconnected.
• Issue 26: CSIOR status is displayed as "Unknown".
Description: A server may show as non-compliant with CSIOR status, "Unknown".
Version affected: All
Resolution/Workaround: An unknown CSIOR state indicates a non-responsive iDRAC on the host. A manual iDRAC reset on the host
fixes this issue.
• Issue 27: Hypervisor installation fails.
Description: Hypervisor installation fails with the error message: Mount network share failed – incorrect IP address or share name.
Version affected: 1.5 and later
Resolution/Workaround: Restart the appliance.
• Issue 28: Health Status is showing Warning for chassis while one or more Power supply is critical.
Description: The overall health information is displayed warning on summary page for VRTX chassis that has power supply in critical
state.
Version affected: All
6
OpenManage Integration for VMware vCenter Version 4.3 Release Notes