Compatibility Matrix
After the OMSA VIB installation is complete, the service automatically stops and the port is closed.
Table 8. Virtual appliance
Port
Number
Protocols Port
Type
Maximum
Encryption
Level
Direction Destination Usage Description
53 DNS TCP None Out OMIVV
appliance to
DNS server
DNS client Connectivity to the DNS server or
resolving the host names.
69 TFTP UDP None Out OMIVV
appliance to
TFTP server
TFTP Client Used for rmware update on 11G
servers with old rmware.
80/443 HTTP/
HTTPS
TCP None Out OMIVV
appliance to
internet
Dell Online Data
Access
Connectivity to the online (Internet)
warranty, rmware, and latest RPM
information.
80 HTTP TCP None In ESXi server to
OMIVV
appliance
HTTP server Used in operating system deployment
ow for post installation scripts to
communicate with the OMIVV
appliance.
162 SNMP
Agent
UDP None In iDRAC/ESXi to
OMIVV
appliance
SNMP Agent
(server)
To receive SNMP traps from managed
nodes.
443 HTTPS TCP 128-bit In OMIVV UI to
OMIVV
appliance
HTTPS server Web services oered by OMIVV. These
Web services are consumed by
vCenter Web Client and Dell Admin
portal.
443 WSMAN TCP 128-bit In/Out OMIVV
appliance to/
from iDRAC/
OMSA
iDRAC/OMSA
communication
iDRAC, OMSA, and CMC or
Management Module communication,
used to manage and monitor the
managed nodes.
445 SMB TCP 128-bit Out OMIVV
appliance to
CIFS
CIFS
communication
To communicate with Windows share.
4433 HTTPS TCP 128-bit In iDRAC to
OMIVV
appliance
Auto Discovery Provisioning server that is used for
auto discovering managed nodes.
2049 NFS UDP/T
CP
None In/Out OMIVV
appliance to
NFS
Public Share NFS public share that is exposed by
OMIVV appliance to the managed
nodes and used in rmware update and
operating system deployment ows.
4001 to
4004
NFS UDP/T
CP
None In/Out OMIVV
appliance to
NFS
Public Share These ports must be kept open to run
the statd, quotd, lockd, and mountd
services by the V2 and V3 protocols of
the NFS server.
11620 SNMP
Agent
UDP None In iDRAC to
OMIVV
appliance
SNMP Agent
(server)
Port used to receive the standard
SNMP alerts by using UDP: 162. Data
from iDRAC, OMSA, and CMC or
Management Module are received to
10 Supported resources