OpenManage Integration for VMware vCenter Version 4.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2011 - 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Overview........................................................................................................................................................ 4 Default virtual appliance configuration ........................................................................................................................... 4 Other documents you may need......................................................................................................................................
1 Overview This document contains updated information about OpenManage Integration for VMware vCenter(OMIVV) and any other Technical Documentation included with the OMIVV software. The OpenManage Integration for VMware vCenter 4.3 provides the following features: • Support for the following: – PowerEdge MX7000 modular infrastructure ◦ PowerEdge MX740c and PowerEdge MX840c servers.
NOTE: For any of the mentioned deployment modes, ensure that you reserve sufficient amount of memory resources to the OMIVV virtual appliance by using reservations. See vSphere Documentation for steps about reserving memory resources. Other documents you may need Go to Dell.com/support/manuals for the following list of documents for vSphere web client: • OpenManage Integration for VMware vCenter Version 4.3 Web Client User’s Guide • OpenManage Integration for VMware vCenter Version 4.
2 Supported resources This chapter contains sections that provides information about the resources that support OpenManage Integration for VMware vCenter.
Server Minimum version PowerEdge R510 1.9.0 or later PowerEdge R515 1.8.6 or later PowerEdge R610 6.1.0 or later PowerEdge R710 6.1.0 or later PowerEdge R710 6.1.0 or later PowerEdge R715 3.0.0 or later PowerEdge R810 2.5.0 or later PowerEdge R815 3.0.0 or later PowerEdge R910 2.5.0 or later PowerEdge M610 6.1.0 or later PowerEdge M610x 6.1.0 or later PowerEdge M710HD 5.0.1 or later PowerEdge M910 2.5.0 or later PowerEdge M915 2.6.0 or later PowerEdge T110 II 1.8.
Server Minimum version R820 1.7.2 or later R920 1.1.0 or later Table 4. BIOS for PowerEdge 13th generation servers Server Minimum version R630 1.0.4 or later R730 1.0.4 or later R730xd 1.0.4 or later R430 1.0.4 or later R530 1.0.2 or later R830 1.0.2 or later R930 1.0.2 or later R230 1.0.2 or later R330 1.0.2 or later T630 1.0.2 or later T130 1.0.2 or later T330 1.0.2 or later T430 1.0.2 or later M630 1.0.0 or later M830 1.0.0 or later FC430 1.0.0 or later FC630 1.0.
Server Minimum Version M640 1.0.0 or later T140 1.0.0 or later T340 1.0.0 or later T640 1.0.0 or later T440 1.0.0 or later R540 1.0.0 or later FC640 1.0.0 or later R6415 1.0.0 or later R7425 1.0.0 or later R7415 1.0.0 or later MX740C 1.0.0 or later MX840C 1.0.0 or later Table 6. iDRAC and Lifecycle Controller for deployment Generation Version iDRAC Lifecycle Controller PowerEdge 11th generation servers 3.35 for Modular, 1.85 for Rack or Tower 1.5.
After the OMSA VIB installation is complete, the service automatically stops and the port is closed. Table 8. Virtual appliance Port Number Protocols Port Type Maximum Encryption Level Direction Destination Usage Description 53 DNS TCP None Out OMIVV appliance to DNS server DNS client Connectivity to the DNS server or resolving the host names. 69 TFTP UDP None Out OMIVV appliance to TFTP server TFTP Client Used for firmware update on 11G servers with old firmware.
Port Number Protocols Port Type Maximum Encryption Level Direction Destination Usage Description manage and monitor the managed nodes. Userdefined Any UDP/T CP None Out OMIVV appliance to proxy server Proxy To communicate with the proxy server. Table 9.
Port Number Protocols Port Type Maximum Encryption Level Direction Destination Usage Description To access the iDRAC configurations from the OMIVV. Used in deployment flow. 4001 to NFS UDP None In/Out 4004 iDRAC to/from OMIVV Public Share For iDRAC to access NFS public share that is exposed by OMIVV appliance. This is used for operating system deployment and firmware update. To access the iDRAC configurations from the OMIVV. Used in deployment flow.
ESXi version support Server generation 11G 12G 13G 14G v6.5 U2 N Y Y Y v6.7 N N Y Y v6.7 U1 N N Y Y NOTE: An MX host is supported only when used with ESXi 6.5 U2 and later. The OpenManage Integration for VMware vCenter supports any of the following vCenter server versions: Table 12. Supported vCenter server versions vCenter version Web client support v6.0 U2 Y v6.0 U3 Y v6.5 Y v6.5 U1 Y v6.5 U2 Y v6.7 Y v6.
Supported features on PowerEdge servers The following features are supported on the hosts managed by OpenManage Integration for VMware vCenter: Table 14.
@ Applicable only for an MX chassis host. Inventory, monitoring, Proactive HA, and firmware update features are supported. ~ Supported only for Rack servers.
3 Important notes This section provides important information that you must consider when you are working on OpenManage Integration for VMware vCenter. • OMIVV supports BIOS mode to deploy hypervisor on the target server. Ensure that you have BIOS mode selected in the reference hardware profile before applying the hypervisor profile. If there is no hardware profile selected, ensure that you manually configure the Boot mode as BIOS and reboot the server before applying the hypervisor profile.