Release Notes

Description: When the power redundancy is lost on the PowerEdge 12th Generation modular servers, the system logs get cleared.
Version affected: 3.0 and later
Resolution/Workaround: None
Issue 9: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.
Description: When a critical entry is made to SEL logs, the health of the server (blade) changes to critical. This is correctly reflected on
the
Host Summary page. However, this is not reflected on the Chassis Summary page. The server health is displayed as warning. If the
chassis was normal earlier, the health of the chassis also changes to warning.
Version affected: 3.0 and later
Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be fixed in the next release of RACADM for
chassis.
Issue 10: The physical disk name is not displayed at data center and cluster level inventory in some situations.
Description: Although the physical disk name is displayed when you view the inventory at the host level, the physical disk name is
displayed empty when you view the inventory of the host at the data center and cluster level.
Version affected: 3.0 and later
Resolution/Workaround: This issue does not affect the functionality of the features, and you can view the inventory at the host level
to see the physical disk name.
Issue 11: Invalid data is displayed for physical disks and virtual disks at data center and cluster inventory intermittently.
Description: When you create connection profile for hosts and run an inventory for the hosts, verify the physical disk and virtual disk
information at the data center, cluster, and host level. On verification, the host level inventory displays valid data whereas in some
situations, at the data center and cluster level, invalid data is displayed along with the valid set of data.
Version affected: 3.0 and later
Resolution/Workaround: This issue is infrequent, and you can press the Refresh option in the same screen to display valid data.
Issue 12: Hard disk option is not disabled in the Deployment wizard for all the servers that do not contain hard disk drives.
Description: While navigating through the Deployment wizard, if the bare-metal servers do not have any hard disk drive, and then the
hard disk option should be disabled on the Global Settings tab. However, the option is available for selection.
Version affected: 2.0 and later
Resolution/Workaround: None
Issue 13: The Initial Configuration wizard is displayed continuously.
Description: The Initial Configuration wizard may be displayed if you click Cancel after selecting the Do not show again option. To
properly read the Do not show again option, the wizard should move to the next page.
Version affected: 2.0 and later
Resolution/Workaround: Select the Do not show again option, and then click Next to move to the next page. Click Cancel to close
the dialog box.
Issue 14: While applying RAID from reference server, the physical disk order is not maintained as it is in the reference server.
Description: After deploying Hardware Profile, the Virtual Disks are created on the physical server. However, the RAID levels are
applied to the same order of the physical disks as in the reference server.
Version affected: All
Resolution/Workaround: None
Issue 15: Using OpenManage Integration to update an Intel Network card with the firmware version of 13.5.2 is not supported.
Description: There is a known issue with Dell PowerEdge 12th generation servers and some Intel Network cards with the firmware
version of 13.5.2. Updating some models of the Intel network cards at this version of firmware fails when the firmware update is
applied using the Lifecycle Controller.
Version affected: All
Resolution/Workaround: Customers with this version of firmware must update the network driver software using an operating system.
If the Intel Network card has a version of firmware other than 13.5.2, you can update using OpenManage Integration.
NOTE:
When using the one-to-many firmware update, avoid selecting Intel network adapters that are at version 13.5.2, as this fails
and stops the update task from updating remaining servers.
Issue 16: Firmware upgrade or downgrade of Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) from firmware version
of 6.2.x or earlier is not supported.
4