Users Guide

Managing System profiles
Configuring hardware profile
Creating hypervisor profile
Creating deployment templates
About deployment wizard
Deployment job timing
Downloading custom Dell EMC ISO images
Device discovery
Discovery is the process of adding supported PowerEdge bare-metal server. After a server is discovered, you can use it for hypervisor and
hardware deployment. See OpenManage Integration for VMware vCenter Compatibility Matrix for the list of the PowerEdge servers
required for deployment. The network connectivity from the Dell EMC bare-metal server’s iDRAC to the OMIVV virtual machine is
required.
NOTE: The hosts with existing hypervisors should not be discovered into OMIVV, instead they should be added to the
vCenter. Add them to a connection profile, and then reconcile with the OpenManage Integration for VMware vCenter by
using the host compliance wizard.
NOTE: If bare-metal servers were discovered earlier than OMIVV 4.0, ensure that you remove the machines from the
bare-metal server list and rediscover them.
NOTE: To perform OS deployment on SD card for 12th generation bare-metal PowerEdge servers, ensure that iDRAC
2.30.30.30 and later is installed.
Manual discovery
You can manually add a bare-metal server that is not added by the discovery process. Once added, the server is displayed in the list of
servers in the Deployment Wizard.
1. In OpenManage Integration for VMware vCenter, on the Manage > Deployment tab, click the icon.
The Add Server dialog box is displayed.
2. In the Add Server dialog box, do the following:
a) In the iDRAC IP Address text box, enter the iDRAC IP Address.
b) In the User Name text box, enter the user name.
c) In the Password text box, enter the password
3. Click Add Server.
The task of adding the server might take few minutes to complete.
Auto discovery in OpenManage Integration for VMware
vCenter
Auto discovery is the process of adding PowerEdge bare-metal server. Once a server is discovered, use it for hypervisor and hardware
deployment. Auto discovery is an iDRAC feature that removes the need of manually discovering a bare-metal server from OMIVV.
Auto discovery prerequisites
Before attempting to discover the PowerEdge bare-metal servers, ensure that OMIVV has been already installed. The PowerEdge servers
with iDRAC Express or iDRAC Enterprise can be discovered into a pool of bare-metal servers. Ensure that there is network connectivity
from the Dell EMC bare-metal server’s iDRAC to the OMIVV appliance.
NOTE:
The hosts with existing hypervisors should not be discovered in to OMIVV, instead add the hypervisor to a
connection profile, and then reconcile with OMIVV by using the Host Compliance Wizard.
For auto discovery to occur, the following conditions must be met:
Power—ensure that you connect the server to the power outlet. The server need not be powered on.
Network connectivity—ensure that the server’s iDRAC has network connectivity and communicates with the provisioning server over
port 4433. You can obtain the IP address by using a DHCP server or manually specify it in the iDRAC configuration utility.
98
Deploying hypervisor