Users Guide

Available virtual appliance version displays wrong
information when the available version is lesser than the
current version
In the OMIVV Admin console, under Appliance Management, Available Virtual Appliance Version displays the modes RPM and OVF
as available.
NOTE: It is recommended that update repository path is set to the latest version and downgrading the virtual appliance
version is not supported.
The 267027 exception is thrown while adding a 12G bare-
metal server with an Express license
During bare-metal discovery, if an incorrect credential is entered, the user account is automatically locked for few minutes. During this
period, iDRAC becomes unresponsive and takes a few minutes before restoring normalcy.
Resolution: Wait for few minutes and retype the user credentials.
During OS deployment on 14G, hardware profile apply fails
due to iDRAC error
During OS deployment on 14G server, a configuration update job is created in iDRAC when the hardware profile is applied. However, the
job fails sometimes and displays a message indicating that a Configuration job is already created.
Resolution: To clear the stale entries and retry the OS deployment, run the racadm jobqueue delete -i
JID_CLEARALL_FORCE command.
OMIVV RPM upgrade fails when proxy is configured with
domain user authentication
If OMIVV appliance is configured with proxy to reach the internet and proxy is authenticated using NTLM authentication, then the RPM
update fails due to the issues in the underlying yum tool.
Version Affected: OMIVV 4.0 and above
Resolution / Work around: Do Back up and Restore to update the OMIVV appliance.
Unable to apply System Profile that has PCIe card in the
FX chassis
The OS deployment fails on a target server if the source server has PCIe card information when using an FX chassis. The System profiles
on the source server has different fc.chassislot ID than the one on the target server. OMIVV tries to deploy the same
fc.chassislot ID on the target server but fails. The System profiles searches for exact instance( FQDD) while applying the profile,
which works successfully on rack servers (identical), but may have few restrictions in modular servers. For example, in FC640, the System
profiles created from one modular server cannot applied on other modular servers in the same FX chassis because of NIC level
restrictions.
Version Affected: 4.1 and later.
Resolution: System profile taken from a FC640 server in slot 1 of a FX2s chassis can only be applied on another FC640 server residing in
the slot 1 of another FX2s chassis.
Bare-metal deployment issues
This section deals with issues found during the deployment process.
Frequently Asked Questions-FAQ