Users Guide
Why does Administration Portal display unreachable
update repository location
If you provide an unreachable Update Repository path, the “Failed: Error while connecting to the URL…. ” error message is displayed on
the top of the Appliance Update view. However, the Update Repository Path is not cleared to the value before update.
Resolution: Move out of this page to another page and ensure that the page is refreshed.
Version Affected: All
Why did system not enter maintenance mode when I
performed one-to-many firmware update
Some firmware updates do not require rebooting the host. In that case, the firmware update is performed without putting the host into
maintenance mode.
Chassis global health still healthy when some of power
supply status has changed to critical
The global health of the chassis about the power supply is based on the redundancy policies and whether the chassis power needs are
satisfied by the PSU that are still online and functional. So even if some of the PSU is out of power, the overall power requirement of the
chassis are met. So the global health of the chassis is Healthy. For more details on the Power Supply and Power Management look in the
user’s Guide for Dell PowerEdge M1000e Chassis Management Controller Firmware document.
Processor version is displayed as “Not Applicable” in
processor view in system overview page
In PowerEdge 12
th
Generation Dell servers and higher generations, the processor version is in the Brand column. In lower generation
servers, processor version is shown in the Version column.
Does OMIVV support vCenter in linked mode
Yes, OMIVV supports up to 10 vCenter servers either in a linked mode or not in a linked mode. For more information about how OMIVV
works in linked mode, see the white paper, OpenManage Integration for VMware vCenter: Working in Linked Mode at www.dell.com.
What are required port settings for OMIVV
NOTE:
When deploying the OMSA agent by using the Fix non-compliant vSphere hosts link available from the
Compliance window in OMIVV, OMIVV starts the http client service and enables port 8080 on releases after ESXI 5.5 to
download the OMSA VIB and install it. After the OMSA VIB installation is complete, the service automatically stops and
the port is closed.
Use the following port settings for OMIVV:
Table 43. Virtual appliance
Port
Number
Protocols Port
Type
Maximum
Encryption
Level
Direction Destination Usage Description
53 DNS TCP None Out OMIVV
appliance to
DNS server
DNS client Connectivity to the DNS server or
resolving the host names.