Release Notes
Version affected: 2.x and later
Resolution/Workaround: Clear the browser cache or log out and log in from the web client.
● Issue 33: OMIVV RPM Upgrade fails when Proxy is configured with Domain user authentication
Description: If OMIVV appliance is configured with proxy to reach the internet and proxy is authenticated using NTLM
authentication, then the RPM update will fail due to the issues in the underlying yum tool.
Version Affected: OMIVV 4.0 and above
Resolution/Workaround: Do Backup and Restore to update the OMIVV appliance.
● Issue 34: Sometimes OMIVV Inventory, Driver Update and Drift detection jobs for vSAN clusters runs for long time and
times out.
Description: If OMIVV appliance is configured to manage vSAN clusters, then sometimes the inventory and firmware update
(if driver included) and drift detection jobs runs for long time and eventually fails after time out. This is because the OMIVV
appliance fails to retrieve the thumbprint information from the registered vCenters in the last reboot. This thumbprint
information is used for collecting driver inventory.
Version Affected: OMIVV 4.2
Resolution: Keep the vCenters server instances up and reboot the OMIVV alliance.
● Issue 35: Unable to apply System Profile that has PCIe card in the FX chassis.
Description: The OS deployment fails on a target server if the source server has PCIe card information when using an FX
chassis. The System profiles on the source server has different fc.chassislot ID than the one on the target server.
OMIVV tries to deploy the same fc.chassislot ID on the target server but fails. The System profiles searches for exact
instance( FQDD) while applying the profile, which works successfully on rack servers (identical), but may have few
restrictions in modular servers. For example, in FC640, the System profiles created from one modular server cannot applied
on other modular servers in the same FX chassis because of NIC level restrictions.
Version Affected: OMIVV 4.1 and later
Resolution/Workaround: System profile taken from a FC640 server in slot 1 of a FX2s chassis can only be applied on another
FC640 server residing in the slot 1 of another FX2s chassis.
Limitations
The following are the limitations for this release of OMIVV:
● If the Dell Cloud server model C6320 contains H730 controller and micro SD card in the riser, the micro SD card might not
be detected in some situations. This limits the OS deployment on the SD card.
● In the Dell Cloud server model C6320, deployment through LSI 2008 is not supported.
● OMIVV cannot access files from SMB version 3 based CIFS.
Installation Prerequisites
For the installation prerequisites, see the section “Prerequisite checklist” in the OpenManage Integration for VMware vCenter
Version 4.2 Web Client Installation Guide at Dell.com/support/manuals.
Installation Procedure
For installation related information, see the OpenManage Integration for VMware vCenter Version 4.2.0 Web Client Installation
Guide at Dell.com/support/manuals.
Installation and Configuration Notes
For installation and configuration-related information, see the OpenManage Integration for VMware vCenter Version 4.2.0 Web
Client Installation Guide at Dell.com/support/manuals.
8