Users Guide
Event name Description Severity Recommended action
The power supplies are
redundant
None Info No action
Power supply redundancy is lost The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
previously operating in a power
redundant mode
Critical Check the event log for power
supply failures. Review system
configuration and power
consumption
Power supply redundancy is
degraded
The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
previously operating in a power
redundant mode
Warning Check the event log for power
supply failures. Review system
configuration and power
consumption
The power supplies are not
redundant
The current power supply
configuration does not meet the
platform requirements to enable
redundancy. If a power supply
fails the system may shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for failures
The power supplies are not
redundant. Insufficient
resources to maintain normal
operations
The system may power down or
operate in a performance
degraded state
Critical Check the event log for power
supply failures. Review system
configuration and power
consumption and upgrade or
install power supplies
accordingly
Internal Dual SD Module is
redundant
None Info No action
Internal Dual SD Module
redundancy is lost
Either one of the SD card or
both the SD cards are not
functioning properly
Critical Replace the failed SD card
Internal Dual SD Module
redundancy is degraded
Either one of the SD card or
both the SD cards are not
functioning properly
Warning Replace the failed SD card
Internal Dual SD Module is not
redundant
None Info Install additional SD card and
configure for redundancy if
redundancy is desired
Chassis events
Power supply redundancy is lost The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
previously operating in a power
redundant mode
Critical Check the event log for power
supply failures. Review system
configuration and power
consumption
Power supply redundancy is
degraded
The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
Warning Check the event log for power
supply failures. Review system
configuration and power
consumption
78 Events, alarms, and health monitoring