Users Guide

4. Ensure that at least one Virtual Disk is seen by the system.
ESXi also installs to an internal SD card.
Why hypervisor deployments failing on Dell PowerEdge
R210 II machines?
A timeout issue on the Dell PowerEdge R210 II systems produces a hypervisor deployment failure error due to the failure of the BIOS to
boot from the attached ISO.
Resolution: Manually install hypervisor on the machine.
Why auto discovered systems are displayed without model
information in Deployment wizard?
This usually indicates that the firmware version installed on the system does not meet the recommended minimum requirements.
Sometimes, a firmware update may not have registered on the system.
Resolution: Cold booting the system or reseating the Blade fixes this issue. The newly enabled account on the iDRAC must be disabled,
and auto discovery reinitiated to provide model information and NIC information to OMIVV.
NFS share is set up with ESXi ISO, but deployment fails
with errors mounting share location
To find the solution:
1. Ensure that the iDRAC is able to ping the appliance.
2. Ensure that your network is not running too slow.
3. Ensure that the ports: 2049, 4001 - 4004 are open and the firewall is set accordingly.
How do I force removal of virtual appliance?
1. Go to Https://<vcenter_serverIPAddress>/mob
2. Enter the VMware vCenter admin credentials.
3. Click Content.
4. Click ExtensionManager.
5. Click UnregisterExtension.
6. Enter the extension key to unregister com.dell.plugin.OpenManage_Integration_for_VMware_vCenter_WebClient, and then click
Invoke method.
7. In the vSphere web client, turn off OMIVV and delete it. The key to unregister must be for the web client.
Entering a Password in the Backup Now Screen Receives
an Error Message
If you are using a low resolution monitor, the Encryption Password field is not visible from the BACKUP NOW window. You must scroll
down the page to enter the encryption password.
126