Users Guide

Table 26. Virtualization events (continued)
Event name Description Severity Recommended action
previously operating in a power
redundant mode
Power supply redundancy is
degraded
The current power operational
mode is non-redundant because
of a power supply exception, a
power supply inventory change,
or a system power inventory
change. The system was
previously operating in a power
redundant mode
Warning Check the event log for power
supply failures. Review system
configuration and power
consumption
The power supplies are
redundant
None Info No action
The power supplies are not
redundant
The current power supply
configuration does not meet the
platform requirements to enable
redundancy. If a power supply
fails the system may shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for failures
The power supplies are not
redundant. Insufficient
resources to maintain normal
operations
The system may power down or
operate in a performance
degraded state
Critical Check the event log for power
supply failures. Review system
configuration and power
consumption and upgrade or
install power supplies
accordingly
Fan redundancy is lost One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans
Critical Remove and reinstall failed fans
or install additional fans
Fan redundancy is degraded One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans.
Warning Remove and reinstall failed fans
or install additional fans
The fans are redundant None Info No action
The fans are not redundant One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans
Info Remove and reinstall failed fans
or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have failed or
have been removed or a
configuration change occurred,
which requires additional fans
Critical Remove and reinstall failed fans
or install additional fans
Proactive HA events
The following table contains the Proactive HA critical, normal, and warning events; includes health update id, component type, and
description:
Table 27. Proactive HA events
Dell Inc provider event id Component type Description
DellServerFan Fan Fan redundancy event
DellServerPower Power Power redundancy event
DellServerIDSDM Storage IDSDM redundancy event
78 Events, alarms, and health monitoring