Users Guide
Host user name requirements:
○ Between 1 and 64 characters long
○ No nonprintable characters
○ No Invalid characters, such as " / \ [ ] : ; | = , + * ? < > @
Host domain requirements:
○ Between 1 and 64 characters long
○ First character must be alphabetical
○ Cannot contain a space
○ No Invalid characters, such as " / \ [ ] : ; | = , + * ? < > @
b. In Active Directory Password, type the password. The password is limited to 127 characters.
c. In Verify Password, type the password again.
d. Perform one of the following actions:
○ To download and store the host certificate, and validate it during all future connections, select Enable Certificate Check.
○ To not store and perform the iDRAC certificate check during all future connections, clear Enable Certificate Check.
• To configure host credentials without Active Directory, perform the following tasks:
a. In User Name, the user name is root, which is the default user name and you cannot change the user name. However, if the
Active directory is set, you can choose any Active directory user and not root.
b. In Password, type the password. The password is limited to 127 characters.
NOTE: The OMSA credentials are the same credentials that are used for the ESXi hosts.
c. In Verify Password, type the password again.
d. Perform one of the following actions:
○ To download and store the host certificate, and validate it during all future connections, select Enable Certificate Check.
○ To not store and perform the host certificate check during all future connections, clear Enable Certificate Check.
5. Click Next.
6. In the Connection Profile Associated Hosts dialog box, select the hosts for the connection profile and click OK.
NOTE: If you select hosts that are running ESXi 6.5 or later, ensure that you click the icon for enabling the WBEM
service on all those hosts.
7. To test the connection profile, select one or more hosts and click Test Connection.
NOTE:
This step is optional and checks whether the host and iDRAC credentials are correct or not. Although this
step is optional, Dell recommends you to test the connection profile.
NOTE: The test connection fails if the WBEM service is not enabled for hosts with ESXi 6.5 or later.
8. To complete the creation of profile, click Next.
Once you click next, all details that you provide in this wizard is saved and you cannot modify the details from the wizard. You can
modify or create more connection profiles for this vCenter detail from the Manage > Profiles Connection Profiles page after
completing the configuration from the configuration wizard. See Modifying connection profile on page 41.
NOTE:
The servers that do not have either an iDRAC Express or Enterprise card, the iDRAC test connection result is not
applicable for this system.
Scheduling inventory jobs
You can configure inventory schedule by using the configuration wizard or OpenManage Integration under the OpenManage Integration
> Manage > Settings tab.
NOTE:
To ensure that OMIVV continues to display updated information, Dell recommends that you schedule a periodic
inventory job. The inventory job consumes minimal resources and does not degrade host performance.
NOTE: The chassis gets discovered automatically after the inventory for all the blades of the chassis are run. If the
chassis is added to a chassis profile, the chassis inventory automatically runs. In an SSO environment with multiple
vCenter servers, the chassis inventory runs automatically with every vCenter when the inventory for any vCenter is run
at a scheduled time.
Appliance configuration for VMware vCenter 33