Release Notes
● Issue 35: CSIOR status is displayed as "Unknown".
Description: A server may show as non-compliant with CSIOR status, "Unknown".
Version affected: All
Resolution/Workaround: An unknown CSIOR state indicates a non-responsive iDRAC on the host. A manual iDRAC reset on
the host fixes this issue.
● Issue 36: Hypervisor installation fails.
Description: Hypervisor installation fails with the error message: Mount network share failed – incorrect IP address or
share name.
Version affected: 1.5 and later
Resolution/Workaround: Restart the appliance.
● Issue 37: NFS mount remains mounted after successful deployment by using ESXi 5.0.
Description: After the hypervisor deployment is complete and the host is added to the vCenter tree, there is an entry in the
Summary page under the data sources called, "remote-install-location (inactive) (unmounted)" for the new host added.
Version affected: 1.5 and later
Resolution/Workaround: None
● Issue 38: Health Status is showing Warning for chassis while one or more Power supply is critical.
Description: The overall health information is displayed warning on summary page for VRTX chassis that has power supply in
critical state.
Version affected: All
Resolution/Workaround: Each power supply status is shown correctly as critical.
● Issue 39: Health Status is showing as Healthy for chassis while Storage status is Warning.
Description: The overall health information is displayed Healthy on summary page for VRTX chassis that has a storage
component as Warning.
Version affected: VRTX firmware version 2.0
Resolution/Workaround: Storage component health status is shown correctly as Warning.
● Issue 40: Blower information is showing as N/A for a chassis when a Blower is removed.
Description: Blower inventory information is displayed as N/A on the Monitor page for VRTX chassis when a Blower is
removed from a slot.
Version affected: 2.0 and later
Resolution/Workaround: You can see the fan inventory before the blower was removed.
● Issue 41: File type '.csv' is not be appended to the file, if the file name is anything other than "Export List".
Description: When we export any of the grid details from any OMIVVC pages (from IE9), the default File Name "ExportList"
is shown. If saved as is, it will be saved as "ExportList.csv". If the file name is changed to anything other than "Export List",
the file will be saved without any extension.
Opening the file will show all details in comma separated value format. Issue is just to append.
Version affected: M1000e firmware version 5.0
Resolution/Workaround:
1. Login to web client from IE 9, and export any grid value from pages like HW profile, Hypervisor profile, Host - firmware
inventory.
2. While saving, change the file name from ExportList to something else, say ExportList123.
3. Save the file with the file extension (in case the default name is changed.)
● Issue 42: I see a web communication error in the vCenter web client after changing the DNS settings in OpenManage
Integration for VMware vCenter?
Description: If you see any kind of web communication error in the vCenter web client while doing any OpenManage
Integration for VMWare vCenter related tasks after changing the DNS settings, clear the browser cache or logout and login
from the web client.
Version affected: 2.x and later
9