Release Notes

NOTE:
When using the one-to-many firmware update, avoid selecting Intel network adapters that are at version 13.5.2, as this
fails and stops the update task from updating remaining servers.
Issue 22: Firmware upgrade or downgrade of Broadcom NetXtreme II 10 Gigabit Ethernet adapter (BCM57712) from
firmware version of 6.2.x or earlier is not supported.
Description: Using the OpenManage Integration to upgrade a Broadcom NetXtreme II 10Gigabit Ethernet adapter
(BCM57712) from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier is not
supported.
Version affected: All
Resolution/Workaround: There is a known issue with the Broadcom NetXtreme II 10Gigabit Ethernet adapter (BCM57712)
where updating the adapter from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier
fails when the update is applied using the Lifecycle Controller. When attempting to perform this update using the
OpenManage Integration, the update may incorrectly show that it completed successfully. However, the firmware update
has failed and remains at the previous level. One way to successfully update the adapter software for the Broadcom
NetXtreme II 10Gigabit Ethernet adapter (BCM57712) is for customers to update the adapter firmware from an operating
system.
Issue 23: Running firmware update may display an error message, The firmware repository file does not exist or is invalid.
Description: While running the Firmware Update wizard, at the data center or cluster level, an error message may be
displayed: The firmware repository file does not exist or is invalid. This may be due to a daily background process that was
unable to download and cache the catalog file from the repository. This occurs if the catalog file is not reachable at the time
the background process runs.
Version affected: All
Resolution/Workaround: After resolving any catalog connectivity issues that may exist, you can reinitiate the background
process by changing the firmware repository location, and then setting it back to the original location. Allow about 5 minutes
for the background process to complete and ensure that there is no @ character present in the credential provided for the
CIFS share.
Issue 24: An error occurs while installing the OpenManage Integration for VMware vCenter.
Description: While installing the OpenManage Integration for VMware vCenter, the following error is displayed: Network card
'VirtualE1000' has a DVPort backing, which is not supported. This could be because the host does not support VDS or
because the host has not joined a VDS.
Version affected: All
Resolution/Workaround: Set the network interface to the VM Network during the OVF installation. After the virtual machine
is created, remap the networking to the VDS port group.
Issue 25: The NIC connection status is not reflected correctly on Dell PowerEdge 12th generation servers.
Description: Under the Dell Server Management tab, the Hardware Inventory Information > NICs section, the Network
Interface Cards may display incorrect connection status as "NO" on the Dell PowerEdge 12th generation servers. This is due
to a defect in recent versions of the Lifecycle Controller firmware. This Lifecycle Controller defect will be addressed in a
future Lifecycle Controller firmware release.
Version affected: All
Resolution/Workaround: None
Issue 26: The Service Tag is not displayed during a firmware update.
Description: In the firmware inventory and on the Select Update Bundles tab, the Service Tag information is not displayed
for the Dell PowerEdge 11th generation servers. This information is not displayed if VMware vCenter does not provide the
Service Tag.
Version affected: All
Resolution/Workaround: You can view the Service Tag information on the Host Overview page from where you launched
the firmware update.
Issue 27: Associated Connection Profile is not displayed in the host compliance page when inventory is not able to get
iDRAC IP for the host.
Description: If the iDRAC IP is not retrieved because of non-responsive iDRAC, the inventory fails and host to be associated
with the connection profile is not displayed on the host compliance page.