Release Notes

Version affected: All
Resolution/Workaround: Perform the following steps:
1. Go to /etc/vmware/vsphere-client/vc-packages/vsphere-client-serenity folder in the vCenter
appliance and see that old data exists, such as:
com.dell.plugin.OpenManage_Integration_for_VMware_vCenter_WebClient-3.0.0.197
2. Manually delete the folder corresponding to the earlier OMIVV version.
3. Restart the vSphere web client service on the vCenter server.
Issue 8: Initial Configuration wizard settings are overridden by default settings each time it is invoked.
Description: After you configure inventory, warranty retrieval schedules; events and alarms in the initial configuration wizard
and then relaunch the configuration wizard again, the previous inventory and warranty retrieval schedules are not retained.
The inventory and warranty schedules are reset to the default settings each time the configuration wizard is invoked,
whereas the events and alarms retain the updated settings.
Version affected: 3.0 and later
Resolution/Workaround: Replicate the previous schedule in the inventory and warranty schedule pages before completing
the wizard functions so that the previous schedule is not overridden by the default settings.
Issue 9: The OpenManage Integration icon is not displayed after backup and restore from an earlier OMIVV version to a
later OMIVV version.
Description: The OpenManage Integration icon is not displayed after restoring an earlier OMIVV version appliance database
to a later OMIVV version appliance.
Version affected: 3.0 and later
Resolution/Workaround: The IP address of the later OMIVV version appliance must be the same as the earlier OMIVV version
appliance for the plug-in to work correctly after restore.
Issue 10: Storage overview returning incorrect number of physical disks for inventory.
Description: Systems with software RAID show incorrect number of physical disks on the storage overview page.
Version affected: All
Resolution/Workaround: None. The ESXi does not support software RAID. If the system has software RAID, it shows
incorrect disks.
Issue 11: System Event Logs are not showing in OpenManage Integration for VMware vCenter vSphere client when power
supply redundancy is lost.
Description: When the power redundancy is lost on the PowerEdge 12th Generation modular servers, the system logs get
cleared.
Version affected: 3.0 and later
Resolution/Workaround: None
Issue 12: Memory data displays a negative value for a host after successful inventory.
Description: The Total Memory capacity displays as "0" and Memory Installable displays a negative value on the Host
Memory overview page. This issue occurs because of some issue in the iDRAC.
Version affected: All
Resolution/Workaround: Restart the system and check if the issue is resolved. If issue is not resolved, you may have to reset
the iDRAC.
Issue 13: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.
Description: When a critical entry is made to SEL logs, the health of the server (blade) changes to critical. This is correctly
reflected on the Host Summary page. However, this is not reflected on the Chassis Summary page. The server health is
displayed as warning. If the chassis was normal earlier, the health of the chassis also changes to warning.
Version affected: 3.0 and later
Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be fixed in the next release of
RACADM for chassis.
Issue 14: The physical disk name is not displayed at data center and cluster level inventory in some situations.
4