Users Guide

8
Virtualization-related Events For Dell PowerEdge
Servers
The following table contains virtualization-related critical and warning events, including event name, description and severity level for
11th, 12th, and 13th generation of PowerEdge servers.
Table 8. Virtualization-related Events of 11th, 12th, and 13th Generation PowerEdge Servers
Event Name Description Severity Recommended action
Dell-Current sensor detected a
warning value
A current sensor in the
specied system exceeded its
warning threshold.
Warning No action
Dell-Current sensor detected a
failure value
A current sensor in the
specied system exceeded its
failure threshold.
Error Put the system into
maintenance mode
Dell-Current sensor detected a
non-recoverable value
A current sensor in the
specied system detected an
error from which it cannot
recover
Error No action
Dell-Redundancy regained Sensor Returned to Normal
Value
Info No action
Dell-Redundancy degraded A redundancy sensor in the
specied system detected that
one of the components of the
redundancy unit has failed but
the unit is still redundant.
Warning No action
Dell - Redundancy lost A redundancy sensor in the
specied system detected that
one of the components in the
redundant unit has been
disconnected, has failed, or is
not present.
Error Put the system into
maintenance mode
Dell - Power supply returned to
normal
Sensor Returned to Normal
Value
Info No action
Dell - Power supply detected a
warning
A power supply sensor reading
in the specied system
exceeded a user denable
warning threshold.
Warning No action
Dell - Power supply detected a
failure
A power supply has been
disconnected or has failed.
Error Put the system into
maintenance mode
87