Users Guide

解决方案:在管理控制台中,将默认更新存储库字段中的路径手动复制到更新存储库路径字段。
在备份和还原 OpenManage Integration for VMware vCenter 后,为何警报设置没有被还原?
还原 OpenManage Integration for VMware vCenter 设备备份不会还原所有警报设置。但是,在 OpenManage Integration for
VMware GUI
中,警报和事件字段显示还原后的设置。
解决方案: OpenManage Integration for VMware GUI 管理设置选项卡中,手动更改事件和警报设置。
Bare Metal Deployment Issues
This section deals with issues found during the deployment process.
Auto-Discovery and Handshake Prerequisites
Prior to running auto-discovery and handshake, make sure that iDRAC and Lifecycle Controller rmware and BIOS versions meet
the minimum recommendations.
CSIOR must have run at least once on the system or iDRAC.
Hardware Conguration Failure
Before initiating a deployment task, make sure the system has completed CSIOR and is not in the process of rebooting.
It is highly recommended that BIOS conguration be run in Clone mode, so that the reference server is an identical system.
Some controllers do not allow creation of a RAID 0 array with one drive. This feature is supported only on high-end controllers,
and the application of such a hardware prole can cause failures.
OS deployment failure on PowerEdge servers running iDRAC version 2.35.35.35
While deploying the ESXi operating system, the host fails to load all the ESXi packages from the OMIVV appliance, displaying the
following message:
Fatal error: 33 (Inconsistent data)
It is recommended that you update the iDRAC rmware to version 2.40.40.40 or later.
在新购买的系统上启用自动查找
主机系统的自动查找功能在默认情况下并未启用;而是必须在购买时申请启用。如果在购买时申请了启用自动查找,在 iDRAC
上会启用 DHCP,并且 admin 帐户被禁用。不需要为 iDRAC 配置静态 IP 地址。它会从网络上的 DHCP 服务器获得一个地址。
要利用自动查找功能,DHCP 服务器或 DNS 服务器(或两者)必须被配置为支持查找进程。出厂过程已运行 CSIOR
如果在购买时未申请自动查找,则可以通过以下步骤启用:
1. 在引导过程中按 <Ctrl + E>
2. iDRAC 设置窗口中,启用 NIC(仅刀片服务器)。
3. 启用自动查找。
4. 启用 DHCP
5. 禁用 admin 帐户。
6. 启用 DHCP 获取 DNS 服务器地址
7. 启用 DHCP 获取 DNS 域名
8. 配置服务器字段中,输入:
<OpenManage Integration virtual appliance IPaddress>:4433
联系 Dell
: 如果没有活动的 Internet 连接,您可以在购货发票、装箱单、帐单或 Dell 产品目录上查找联系信息。
82