Release Notes
Resolution/Workaround: Restart the system and check if the issue is resolved. If issue is not resolved, you may have to reset the
iDRAC.
Version Aected: All
Issue 13: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.
Description: When a critical entry is made to SEL logs, the health of the server (blade) changes to critical. This is correctly reected
on the Host Summary page. However, this is not reected on the Chassis Summary page. The server health is displayed as warning.
If the chassis was normal earlier, the health of the chassis also changes to warning.
Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be xed in the next release of RACADM for
chassis.
Version Aected: 3.0 and later
Issue 14: OMIVV plug-in might display the Download and Install status in some situations.
Description: After OMIVV is installed and registered with the vCenter Server, the status of OMIVV plug-in might not display the
Enabled status in some situations. The Download and Install status is displayed instead of the Enabled status.
Resolution/Workaround: If there are any concerns with registering the OMIVV plug-in, contact technical support.
Version Aected: 3.0 and later
Issue 15: The physical disk name is not displayed at datacenter and cluster level inventory in some situations.
Description: Although the physical disk name appears when you view the inventory at the host level, the physical disk name appears
empty when you view the inventory of the host at the datacenter and cluster level.
Resolution/Workaround: This issue does not aect the functionality of the features and you can view the inventory at the host level
to see the physical disk name.
Version Aected: 3.0 and later
Issue 16: Invalid data is displayed for physical disks and virtual disks at datacenter and cluster inventory intermittently.
Description: When you create connection prole for hosts and run an inventory for the hosts, verify the physical disk and virtual disk
information at the datacenter, cluster, and host level. On verication, the host level inventory displays valid data whereas in some
situations, at the datacenter and cluster level, invalid data is displayed along with the valid set of data.
Resolution/Workaround: This issue is infrequent and you can press the Refresh option in the same screen to display valid data.
Version Aected: 3.0 and later
Issue 17: Adobe Flash error is displayed while viewing the inventory of power monitoring and physical disks information at the
datacenter and cluster level.
Description: In some situations, while viewing the inventory details of a host at the datacenter and cluster level, Adobe Flash player
error 1069 is displayed for the Power Monitoring information. Similarly, Adobe Flash player error 1034 is displayed while viewing the
physical disk information. When either of these error appears, you can only refresh the screen and cannot view other inventory
details. Additionally, you cannot perform actions on Update Firmware and Export.
Resolution/Workaround: This issue is infrequent and you should close dot net client and login again to view another screen. The
Power Monitoing and physical disk information can be only seen from the host inventory screen.
Version Aected: 3.0 and later
Issue 18: Processor Version is not displayed for 12th generation servers on the overview rmware page of host.
Description: For 12th generation servers, processor version is not displayed on the overview page for rmware inventory. This
information is available for 11th and earlier generation systems.