Users Guide
• Work In Progress
• Alarms
Dell alarm information displays in this notification area portlet.
5. Scroll down to view the Dell Server Management portlet.
Service Tag The Service Tag for your Dell PowerEdge server. Use this ID when you call for support.
Model Name Displays the servers model name.
Fault Resilient
Memory
This is a BIOS attribute and is enabled in the BIOS during initial setup of the server and displays the memory
operational mode of the server. You need to restart your system when you change memory operational
mode value. This is applicable for R620, R720, T620, M620 servers with ESXi 5.5 or later version. This is
applicable for 12th generation of PowerEdge servers and above that support Fault Resilient Memory option,
running ESXi 5.5 or later version. The four different values are:
• Enabled and Protected: This value indicates that the system is supported and operating system version
is ESXi 5.5 or later and the memory operational mode in BIOS is set to FRM.
• Enabled and Not Protected: This value indicates that it supports the system with operating system
version lesser than ESXi 5.5.
• Disabled: This value indicates that it supports valid systems with any operating system version and here
memory operational mode in BIOS is not set to FRM.
• Blank: If memory operational mode in BIOS is not supported the FRM attribute is not displayed.
Non-Uniform
Memory Access
(NUMA) Fault
Resilient Memory
(FRM)
NUMA FRM is a new memory operating mode available on the BIOS settings of high-end Dell’s 13th
generation of PowerEdge systems with at least two or four processors. This mode establishes an area of
memory that is fault-resilient on all CPUs, providing the same protection to the hypervisor against
uncorrectable memory errors that would affect it, as well as maintaining NUMA memory functionality and
performance. The four different values are:
• NUMA Enabled and Protected: This value indicates that the system is supported and operating system
version is ESXi 5.5 or later and the memory operational mode in BIOS is set to NUMA FRM.
• NUMA Enabled and Not Protected: This value indicates that it supports the system with operating
system version lesser than ESXi 5.5.
• Disabled: This value indicates that it supports valid systems with any operating system version and here
memory operational mode in BIOS is not set to NUMA FRM.
• Blank: If memory operational mode in BIOS is not supported the NUMA FRM attribute is not displayed.
Identification
• Host name
The name of your Dell host.
• Power State
Displays if your power is ON or OFF.
• iDRAC IP
Displays the iDRAC IP address.
• Management IP
Displays the management IP address.
• Connection Profile
Displays the connection profile name for this host.
• Model
Displays the Dell server model.
• Service Tag
Displays the Service Tag for the server.
• Asset Tag
Displays the Asset tag.
• Warranty Days Left
Displays the days left for the warranty.
Monitoring a Single Host 65