Users Guide

12. Select Apply Changes, and the temperature warning event is generated. To cause another event, restore the original settings
using the same Set to Values option. Events are generated as warnings, and then to a normal state. If everything is working
properly, navigate to the vCenter Tasks & Events view; a temperature probe warning event should be displayed.
NOTE: There is a lter for duplicate events; if you try to trigger the same event too many times in a row, you will only
receive one event. Allow at least 30 seconds between events to see all events.
I Have the OMSA Agent Installed on a Dell Host System, But I Still Get an Error Message That
OMSA is Not Installed. What Should I Do?
To resolve this issue on an 11th generation server:
1. Install OMSA with the Remote Enablement component on the host system.
2. If you are using the command line to install OMSA, make sure to specify the -c option. If OMSA is already installed, reinstall it
with the -c option and restart the service:
srvadmin-install.sh -c
srvadmin-services.sh restart
For an ESXi host, you must install OMSA VIB using the VMware Remote CLI tool, and reboot the system.
Can the OpenManage Integration for VMware vCenter Support ESXi with Lockdown Mode
Enabled?
Yes. Lockdown Mode is supported in this release on hosts ESXi 5.0 and above.
When I tried to use lockdown mode, it failed.
When I added a host to the connection prole in lockdown mode, the inventory kicked o but failed stating that “No Remote Access
Controller was found or Inventory is not supported on this host.” Inventory is supposed to work for a host in lockdown mode, right?
If you put the host in lockdown mode or remove a host from lockdown mode, you must wait 30–minutes before performing the next
operation on the OpenManage Integration for VMware vCenter.
What Setting Should I Use For UserVars.CIMoeMProviderEnable With ESXi 4.1 U1?
Set UserVars.CIMoemProviderEnabled to 1.
I Am Using A Reference Server to Create a Hardware Prole But it Failed. What Should I Do?
Check to make sure that minimum recommended versions of iDRAC rmware, Lifecycle Controller rmware, and BIOS are installed.
To make sure that the data retrieved from the reference server is current, enable Collect System Inventory On Restart (CSIOR),
and restart the reference server prior to extraction of data.
I Am Attempting to Deploy ESXi on a Blade Server and it Failed. What Should I Do?
1. Make sure the ISO location (NFS path) and staging folder paths are accurate.
2. Make sure the NIC selected during assignment of server identity is on the same network as the virtual appliance.
3. If using static IP address, make sure the network information provided (including subnet mask and default gateway) is accurate.
In addition, , make sure the IPaddress is not already assigned on the network.
4. Make sure at least one Virtual Disk is seen by the system. ESXi also installs to an internal RIPS SD card.
Why are My Hypervisor Deployments Failing on my Dell PowerEdge R210 II Machines?
A timeout issue on Dell PowerEdge R210 II systems produces a hypervisor deployment failure error due to the failure of the BIOS to
boot from the attached ISO. To resolve this issue, manually install hypervisor on the machine.
123