Users Guide
Table Of Contents
- OpenManage Integration for Microsoft System Center Version 7.3 for Microsoft Endpoint Configuration Manager and System Center Virtual Machine Manager Unified User’s Guide
- Contents
- Introduction to OMIMSSC
- OMIMSSC license
- OMIMSSC components
- Support Matrix for OMIMSSC
- Deploy OMIMSSC
- Enroll Microsoft console in OMIMSSC
- Manage OMIMSSC and its components
- Backup and Restore OMIMSSC Appliance
- Uninstall OMIMSSC
- Upgrade OMIMSSC
- Manage Credential and Hypervisor profiles
- Discover devices and sync servers with OMIMSSC console
- Remove devices from OMIMSSC
- Views in OMIMSSC
- Manage Operational Templates
- Predefined Operational Templates
- About reference server configuration
- About reference Modular System configuration
- Create Operational Template from reference servers
- Create Operational Template from reference Modular Systems
- Create clusters using Operational Template
- View Operational Template
- Edit Operational Template
- Configure system specific values (Pool values) using Operational Template on multiple servers
- Assign Operational Template and Run Operational Template Compliance for servers
- Deploy Operational Templates
- Unassign Operational Template
- Delete Operational Template
- Deploy operating system using OMIMSSC
- Provision devices using OMIMSSC
- Update firmware using OMIMSSC
- Manage devices using OMIMSSC
- Deploy Azure Stack HCI cluster
- Troubleshooting
- Resources required for managing OMIMSSC
- Verifying permissions for using OMIMSSC console extension for MECM
- Verifying PowerShell permissions for using OMIMSSC console extension for SCVMM
- Install and upgrade scenarios in OMIMSSC
- Enrollment failure
- Failure of test connection
- Failure to launch OMIMSSC after installing MECM console extension
- Failure to connect to OMIMSSC console extension for SCVMM
- Error accessing console extension after updating SCVMM R2
- IP address not assigned to OMIMSSC Appliance
- SCVMM crashes while importing OMIMSSC console extension
- Failed to login to OMIMSSC console extensions
- SC2012 VMM SP1 crashing during update
- OMIMSSC admin portal scenarios
- Discovery, synchronization and inventory scenarios in OMIMSSC
- Failure to discover servers
- Failure to auto discover iDRAC servers
- Discovered servers not added to All Dell Lifecycle Controller Servers collection
- Failure to discover servers due to incorrect credentials
- Creation of incorrect VRTX chassis group after server discovery
- Unable to synchronize host servers with enrolled MECM
- Empty cluster update group not deleted during autodiscovery or synchronization
- Failure to create cluster while applying cluster features
- Unable to retrieve the Cluster Aware Update job status
- Failure to perform maintenance-related tasks on rediscovered servers
- Generic scenarios in OMIMSSC
- Firmware update scenarios in OMIMSSC
- Failure of test connection for local update source
- Failure to create DRM update source
- Failure to create repository during firmware update
- Failure to update firmware of clusters
- Failure of firmware update because of job queue being full
- Failure of firmware update when using DRM update source
- Firmware update on components irrespective of selection
- Failure to delete a custom update group
- Failure to update WinPE image
- Changing of polling and notification bell color after updating the frequency
- Operating system deployment scenarios in OMIMSSC
- Server profile scenarios in OMIMSSC
- LC Logs scenarios in OMIMSSC
- Appendix I: Time zone attribute values
- Appendix II: Populate Pool values
- Accessing support content from the Dell EMC support site
Table 14. System specific values for Hardware component (continued)
Component Group Name Attribute Name
Network iSCSI Initiator Parameters CHAP Secret
Network iSCSI Initiator Parameters Default Gateway
Network iSCSI Initiator Parameters IP Address
Network iSCSI Initiator Parameters IPv4 Address
Network iSCSI Initiator Parameters IPv4 Default Gateway
Network iSCSI Initiator Parameters IPv4 Primary DNS
Network iSCSI Initiator Parameters IPv4 Secondary DNS
Network iSCSI Initiator Parameters IPv6 Address
Network iSCSI Initiator Parameters IPv6 Default Gateway
Network iSCSI Initiator Parameters IPv6 Primary DNS
Network iSCSI Initiator Parameters IPv6 Secondary DNS
Network iSCSI Initiator Parameters iSCSI Name
Network iSCSI Initiator Parameters Primary DNS
Network iSCSI Initiator Parameters Secondary DNS
Network iSCSI Initiator Parameters Subnet Mask
Network iSCSI Initiator Parameters Subnet Mask Prefix
Network iSCSI Secondary Device Parameters Secondary Device MAC Address
Network iSCSI Second Target Parameters Boot LUN
Network iSCSI Second Target Parameters CHAP Secret
Network iSCSI Second Target Parameters CHAP ID
Network iSCSI Second Target Parameters IP Address
Network iSCSI Second Target Parameters iSCSI Name
Network iSCSI Second Target Parameters TCP Port
Network iSCSI Secondary Device Parameters Use Independent Target Name
Network iSCSI Secondary Device Parameters Use Independent Target Portal
Network Main Configuration Page Virtual FIP MAC Address
Network Main Configuration Page Virtual iSCSI Offload MAC Address
Network Main Configuration Page Virtual MAC Address
Network Partition n Configuration Virtual MAC Address
Network Main Configuration Page Virtual Port GUID
Network Main Configuration Page Virtual World Wide Node Name
Network Partition n Configuration Virtual World Wide Node Name
Network Main Configuration Page Virtual World Wide Port Name
Network Partition n Configuration Virtual World Wide Port Name
Network Main Configuration Page World Wide Node Name
Network Partition n Configuration World Wide Node Name
FC Fibre Channel Target Configuration Boot Scan Selection
Appendix II: Populate Pool values 109