The Dell EMC Repository Manager (DRM) stops when repository of complete MX7000 chassis group is created using its
inventory.xml file.
Workaround:
Select only MX7000 chassis and servers. Ensure that the inventory does not contain IOMs and storage sleds.
● Issue 26
Description:
While discovering servers using IP Address Range and specifying the IP addresses to exclude, if you change any IP value
specified in the IP Address Range after specifying the IP address to exclude, the following error is displayed, The IP
address range that you want to exclude is not within the specified IP address range.
Workaround:
As a workaround, do not change the IP Address Range values after you have specified the exclude IP address range to
discover the servers.
● Issue 27
Description:
In the Modular System View page, the Firmware Version is not displayed after restoring the MX7000 modular system
which is discovered in the previous version of OMIMSSC.
Workaround:
As a workaround, rediscover the MX7000 modular system to view the firmware version.
● Issue 28
Description:
In the Maintenance Center page, if disk attached to AHCI controller is attempted for an update through cluster aware
method, the updated Post Successful Update Version of the disk component will not be reflected.
Workaround:
As a workaround, after the CAU job is completed, restart the cluster node or nodes where AHCI controller is an applicable
update and refresh the inventory.
● Issue 29
Description:
In the Maintenance Center page, while performing Run Update using Cluster Aware Update method, user cannot
update the firmware version of operating system driver pack.
Workaround:
As a workaround, you can update the operating system driver pack from iDRAC console, or can directly run the DUP on the
node operating system.
● Issue 30
Description:
In Modular Systems view, Operational Template Compliance Summary displays noncompliant with zero noncompliant
attributes for MX7000.
Cause:
If MX7000 discovered in OMIMSSC is at 1.10.00 firmware version, attributes present under following specified groups
cannot be configured using modular system type Operational Template and these attributes should be modified outside of
OMIMSSC
○ LocalAccessConfiguration
○ TimeConfig
○ Power
○ SessionConfiguration
Workaround:
Recapture the Operational Template and rerun the compliance.
● Issue 31
Description:
12
Known issues and resolutions