Users Guide

Table Of Contents
Troubleshooting
Topics:
Data is not displayed on the Feature Management Dashboard
A task run on the Feature Management Dashboard fails
Feature Management alerts
The Management Server (MS) is not functioning, and therefore, tasks associated with it cannot be completed (Health
Service of the Feature Management Host Server is nonfunctional)
Data is not displayed on the Feature Management
Dashboard
About this task
In a distributed setup, the SCOM Management Server, where the Dell EMC Windows Server Agent-based and iDRAC7 or
iDRAC8 SNMP Management Pack is installed first, is selected to host all feature management activities such as discoveries,
alerts, and tasks. The SCOM Management Server on which the Dell EMC Windows Server Agent-based and iDRAC7 or iDRAC8
SNMP Management Pack is installed first populates the Feature Management Dashboard. However, if you have manually
imported the Feature Monitoring management pack without running the installer on the SCOM Management Server, the Feature
Management Pack host is not selected. Therefore, data is not displayed on the Feature Management Dashboard.
To populate the Feature Management Dashboard:
Steps
1. In the SCOM console, click Authoring.
2. In the Authoring section, expand Management Pack Objects.
3. Click Object Discoveries.
4. In the Look for box, search for Dell Feature Management Host Discovery.
5. Right-click Dell Feature Management Host Discovery, and then select Overrides > Override the Object Discovery >
For all objects of class: Dell Feature Management Host Discovery.
6. To run the feature management activities, select FmpHostFqdn.
7. Set the override value to the FQDN of the SCOM Management Server.
A task run on the Feature Management Dashboard
fails
About this task
Performing upgrade task on the Feature Management Dashboard can result in data loss. For example, if there are any
dependencies or associations on the monitoring feature being modified then upgrade task fails by displaying a message.
CAUTION: Overriding task parameters may result in management pack or operational data loss.
To resolve this issue, do the following:
Steps
1. Start the SCOM console and click Monitoring.
2. In the Monitoring pane, browse to Dell EMC > Feature Management Dashboard.
11