Users Guide

Table Of Contents
Dell EMC Chassis Monitoring feature
The Dell EMC chassis monitoring feature supports discovery and monitoring of Dell EMC Chassis Management Controller/
OpenManage Enterprise Modular (CMC/OME-M) on PowerEdge MX7000, PowerEdge FX2/ FX2s chassis, PowerEdge VRTX
chassis, PowerEdge M1000E chassis, and Dell OEM Ready chassis using:
SNMP and/or WS-Man protocol
Redfish
Dell EMC Chassis monitoring feature also supports Detailed monitoring of individual chassis components in the supported
Microsoft System CenterOperations Manager.
Management Packs
Table 11. Management Packs required for the Dell EMC chassis monitoring feature
Feature Default location of Management
Packs
Management Packs
Dell EMC Chassis Monitoring
Library
%PROGRAMFILES%\Dell
Management Packs\Server
Mgmt Suite\7.2\Library
Monitored Management Packs
%PROGRAMFILES%\Dell
Management Packs\Server
Mgmt Suite\7.2\Chassis
Monitoring
Library
Dell.Connections.HardwareLibrary.mp
Dell.OperationsLibrary.Common.mp
Monitored Management Packs
Dell.CMC.SDK.mp
Dell.Model.CMC.mp
Dell.CMC.Sync.mp
Dell.View.SDKCMC.mp
Configuration prerequisites
Ensure that SNMP ports on firewall are enabled.
Ensure that Dell Device Helper is installed.
Ensure that there is WS-Man connectivity between the Management Server and the Managed Node.
Dell EMC Chassis Monitoring requirements
For slot discovery and correlation to work, ensure that you have Dell Device Helper utility installed.
To monitor Chassis controller, IO Module, IO Module Group, Power Supply, and Power Supply Group components.
To monitor the health of Chassis devices, associate the community string Run As account with the SNMP Monitoring
Account with the target as Dell Modular Chassis class or respective Chassis object (if you have different Run As accounts
for different Chassis devices).
To discover Chassis Slots and Chassis Slot Summary for Dell EMC Chassis Management Controller/OpenManage Enterprise
Modular (CMC/OME-M), create Run As Accounts and associate it to the profiles Dell CMC Login Account Run As
Profiles. Also, enable the CMC Slot Discovery from the SCOM console.
To perform Chassis Detailed monitoring, create Run As Accounts with WS-Man credentials that are required for accessing
the Dell EMC CMC/OME-Ms, and associate it to the profiles Dell CMC Login Account Run As Profiles.
NOTE:
If you are using AD domain credentials for Dell EMC CMC/OME-M, then, enter the credentials in the following
format: username@domainname.com
Configuring Dell EMC Chassis Management Controller/ OpenManage Enterprise Modular (CMC/
OME-M) feature for correlating Server Modules with the Chassis Slot summary
To configure Dell EMC Chassis Management Controller/OpenManage Enterprise Modular (CMC/OME-M) feature for
correlating server modules, create Run As Accounts and associate it to Run As Profiles to populate chassis slot summary.
1. Create a Run As Account of type Simple Authentication that has privileges to connect to the CMC/OME-M on the chassis.
Also, use the Basic or Digest Run As Account types for configuring the user credentials.
94
Reference topics