Users Guide

Table Of Contents
Other issues
Resolve issues in the Dell EMC Feature Management Dashboard
When using the Restore feature in OMIMSSC, some of the following issues are observed on the Dell EMC Feature Management
Dashboard:
The OMIMSSC version is indicated as 7.1 because of an invalid FQDN or when FQDN
information is not provided
When you provide wrong management server FQDN or do not provide the management server FQDN during restore operation
in the OMIMSSC Admin portal, the available version of appliance for the monitoring features is indicated as 7.1 on Dell EMC
Feature Management Dashboard.
1. After the Restore operation is complete, in the SCOM console, select Authoring.
2. Expand Management Pack Objects.
3. Double-click Object Discoveries.
4. In the Look for field, search for Dell Feature Management Host Discovery.
5. Right-click Dell Feature Management Host Discovery, and then click Overrides > Override the Object Discovery >
For all objects of class: Management Server.
6. Select FMP host FQDN, and then set the override value to FQDN of the management server used during the restore
operation. To retrieve FQDN name of the FMP host:
a. Log in to OMIMSSC Admin portal.
b. Select Jobs and Logs Center > Generic Logs > Appliance logs.
c. In Activity Logs, view the following message:
Information: The Dell registry entry on the MS with FQDN <name> has been updated.
7. Click OK.
The Feature Management Dashboard shows blank about the remaining management
servers
When the management server used for enrollment in the OMIMSSC Admin Portal is removed from the SCOM management
group, the Dell EMC Feature Management Dashboard displays blank about the remaining management servers. To recover the
Feature Management dashboard feature:
1. Update the service pack.
2. Start the management server that had been removed from the management group.
3. At the Command Prompt window, run the following command:Run reg export
HKEY_LOCAL_MACHINE\SOFTWARE\Dell\Dell Server Management Pack Suites c:\Export.txt
4. Start any of the management servers in the management group.
5. Copy the exported C:\Export.txt file to the management server.
6. At the Common Prompt window, run reg import c:\Export.txt.
7. Complete steps 16 in the The OMIMSSC version is indicated as 7.1 because of an invalid FQDN or when FQDN information
is not provided section.
8. Click OK.
The Feature Management Dashboard indicates different OMIMSSC versions for
Server and Rack Workstation and Chassis monitoring features
The Feature Management Dashboard displays two entries of OMIMSSC versions as availableOne each for Dell EMC Server
and Rack workstation Monitoring Feature and Dell EMC Chassis Monitoring Feature. For example, server monitoring indicates
version 7.1, but chassis indicates version 7.2. To remove the monitoring features which have the available version as 7.1 from
Feature Management Dashboard, do the following:
88