Users Guide

Table Of Contents
Troubleshooting
Topics:
Deployment of OMIMSSC appliance and OMIMSSC Admin Portal-related issues
Enrollment of SCOM Management Group with OMIMSSC appliance-related issues
De-enrollment of SCOM Management Group with OMIMSSC appliance-related issues
Discovery and monitoring Dell EMC devices-related issues
Other issues
Deployment of OMIMSSC appliance and OMIMSSC
Admin Portal-related issues
After deploying the OMIMSSC appliance, an IP address is not
assigned to the OMIMSSC appliance
After creating and starting the appliance, the IP address is not assigned or displayed on the Command Line Interface (CLI).
WorkaroundCheck if the virtual switch, which is mapped to a physical switch, is configured correctly, and then connect to the
OMIMSSC appliance.
Unable to start the OpenManage Integration Dashboard in the
SCOM console
About this task
After enrollment, the OpenManage Integration Dashboard is not loading in the SCOM console, or if there is any change in the
OMIMSSC Appliance IP.
WorkaroundUpdate the OMIMSSC appliance IP under Unit Monitors:
Steps
1. In the left pane of the SCOM console, select Authoring.
2. Select Authoring > Management Pack Objects > Monitors.
3. In the Look for field, under Management Server, search for Dell EMC SDK Override Appliance IP.
4. Right-click Dell EMC SDK Override Appliance IP, and then click Override > Override the Monitor > For all objects of
class.
The Override properties wizard is displayed.
5. Select Dell EMC Appliance IP under parameter name.
6. Update the Override value and click OK.
NOTE: Ensure that you do not select any other override parameters.
Unable to log in to the OMIMSSC Admin portal by using the Mozilla
Firefox browser
When accessing the OMIMSSC admin portal by using the Mozilla Firefox browser, the following warning message is displayed:
19
82 Troubleshooting