Users Guide

Table Of Contents
6. Enable the Chassis monitoring feature by using the Dell EMC Feature Management Dashboard.
Perform the Sync with Microsoft System Center from OMIMSSC console operation to complete the discovery of the chassis
devices that are discovered in the SCOM console.
Configuration of SNMP RunAsAccount on the SCOM
console for chassis
After discovering Dell EMC PowerEdge Chassis, to receive alerts, you must manually enable the option to send alert
notifications from the Dell EMC Chassis Management Controller or OpenManage EnterpriseModular (CMC/OME-M) to the
SCOM console.
On the SCOM console, a DellEMC_OMIMSSC_SNMP_RunAsAccount account of the Community String type is created on
the SCOM console. A corresponding Run As Configuration profileSNMP Monitoring Account is created with the SNMP v1
or v2 Community String. By default, the DellEMC_OMIMSSC_SNMP_RunAsAccount is associated with the Dell EMC Hardware
class. To update the SNMP v1 or v2 Community String or change the associated class, see Create Run-As-Account for SNMP
monitoring on page 122 and Associate multiple Run-As accounts on page 123.
Chassis monitoring feature in OMIMSSC
You can use the Monitoring pane of the Operations Manager to select views that provide complete health information of
the discovered Dell EMC Chassis Management Controller/OpenManage Enterprise Modular (CMC/OME-M) devices. The Dell
EMC Chassis monitoring feature discovers and monitors the health of the Dell CMC/OME-M devices. The Severity levels of
discovered devices on page 102 indicates the health of the Dell CMC/OME-M devices on the network.
Chassis Monitoring includes monitoring the health of the Dell chassis devices, both at regular intervals and on occurrence of
events.
NOTE:
To perform the Dell EMC Chassis Detailed monitoring, associate the WS-Man credentials Run As account that is
required for accessing the Dell CMCs with the target as Dell Modular Chassis class or respective CMC object (if you have
different Run As accounts for different CMC/OME-M devices) to the profileDell CMC Login Account Run As Profile.
Monitored chassis views on the SCOM console
The OMIMSSC appliance provides the following types of views for monitoring Dell EMC chassis under Monitoring > Dell EMC
on the SCOM console:
View alerts of the monitored Dell EMC Chassis on page 56
View the Diagram Views of chassis on page 57
View performance and power monitoring of PowerEdge chassis on the SCOM console on page 58
View the State Views of chassis on page 58
View alerts of the monitored Dell EMC Chassis
About this task
The alerts view for the monitored chassis is available for managing hardware and storage events from Dell EMC Chassis
Management Controller/OpenManage Enterprise Modular (CMC/OME-M) devices. The SNMP traps that are sent by Chassis
devices are displayed by the Dell EMC Chassis monitoring feature.
To view the Chassis monitoring alerts:
Steps
1. In the left pane of the SCOM console, select Monitoring.
2. Expand Dell EMC > Dell EMC Alerts Views.
The following alert views are displayed:
Dell EMC Chassis AlertsSNMP traps from the discovered Chassis devices are displayed.
Dell EMC Chassis Alert Views
56
Discovery and monitoring of Dell EMC chassis using OMIMSSC