Users Guide

Table Of Contents
For more information about the available performance and power monitoring views, see Performance and power monitoring
views displayed by different monitoring features of OMIMSSC on page 113.
3. To view the System Board Usage metrics, select Dell EMC Performance and Power Monitoring > Dell EMC System
Board Usage. See Performance and power monitoring views displayed by different monitoring features of OMIMSSC on
page 113.
4. Select the counters from the individual performance views and select the time range for which the values are required.
The data that are collected is represented in a graphical format for each system.
Results
A unit monitor monitors the performance counter over two successive cycles to check if it exceeds the configured critical
threshold value. When the critical threshold value is exceeded, the server changes state and a critical alert is generated. This
unit monitor is disabled by default. You can override (enable) the threshold values from the Authoring pane of the SCOM
console. Unit monitors are available under the Dell Server objects for the Licensed monitoring feature. To enable the unit
monitors and set threshold values of unit monitors, see Enable performance and power monitoring unit monitors on page 47.
NOTE: Power monitoring is applicable only for Dell EMC PowerEdge Servers with power monitoring capability attribute. It is
enabled only when the detailed edition of Dell EMC Server and Rack Workstation Monitoring feature is present.
NOTE: Disk Performance View - iSM (%) is disabled by default and appears only when the detailed edition of the Dell EMC
Server and Rack Workstation Monitoring feature is installed and imported.
Enable performance and power monitoring unit monitors
Steps
1. In the left pane of the SCOM console, click Authoring.
2. Expand Management Pack Objects, and then select Monitors.
3. In the working pane, in the Look for field, search for Performance.
A list of devices whose performance is monitored is listed.
4. Scroll down until you find Dell Server and expand Performance.
The performance unit monitors associated with the Dell Servers are listed.
5. Right-click the unit monitor that you want to enable, and then click Overrides > Override the Monitor > For all objects
of class: Dell Server.
6. In the Override Properties dialog box:
a. In the Enabled row, set the Override Value to True.
b. In the Management Pack section, select a management pack from the drop-down list.
To create a management pack for OMIMSSC, click New.
7. Click Apply.
View the State Views of PowerEdge servers and rack workstations
Steps
1. In the left pane of SCOM, select Monitoring, and then expand Dell EMC > Dell EMC State Views.
The status of Dell EMC servers and rack workstations that are managed by SCOM on the network is displayed. See State
views displayed by different monitoring features of OMIMSSC on page 112.
2. To view data about a component, select a component.
Details are displayed in the Detail View section.
NOTE: The group health is a rollup status of subcomponent health.
Discovery and monitoring of PowerEdge servers by using the licensed monitoring features of OMIMSSC 47