Users Guide

Table Of Contents
Health services-related registry entries are updated under HKEY_LOCAL_MACHINE > SYSTEM > CurrentControlSet >
Services > HealthService > Parameters.
Persistence Version Store Maximum Registry Path is set to 131072.
Maximum Global Pending Data Count Registry is set to 20408.
State Queue Items Registry is set to 20480.
Persistence checkpoint Depth Maximum Registry is set to 20971520.
Microsoft Monitoring Agent Health Services are started.
NOTE: For more information about registry key settings, see https://docs.microsoft.com/en-us/archive/blogs/.
During the enrollment of SCOM Management Servers with OMIMSSC appliance for SCOM, the following Dell EMC management
packs for Alert Relay Servers are automatically imported to the SCOM console: Dell EMC Alert Relay Server Model and Dell
EMC Alert Relay Server View.
Monitoring views of Dell EMC Alert Relay Servers
Steps
1. In the left pane of the SCOM console, select Monitoring, and then expand:
a. Dell EMC > Dell EMC Diagram Views > Dell EMC Alert Relay Server Diagram View to view a hierarchical and
graphical representation of Alert Relay Servers on the network.
b. Dell EMC > Dell EMC State Views > Dell EMC Alert Relay Server State View to view the status of Alert Relay
Servers managed by SCOM on the network.
2. To view more information, select an Alert Relay Server in the list.
The details of Alert Relay Servers are displayed in the Detail View section.
Synchronize Alert Relay Servers with OMIMSSC appliance for
SCOM
Steps
1. In the left pane of the SCOM console, select Monitoring and expand Dell EMC OpenManage Integration Views > Dell
EMC OpenManage Integration Dashboard.
2. Log in to OMIMSSC by using the local administrative privileges of the Management Server.
3. On the home page, scroll down to the Synchronized SCOM Management Servers and Dell EMC Alert Relay Servers
section and click Sync with SCOM MS.
4. After the sync task is complete, the Alert Relay Servers count is updated. Click View Alert Relay Servers to view the
discovered Alert Relay Servers.
Next steps
Wait for 15 minutes for the OMIMSSC appliance to be updated with new Alert Relay Server information, and then continue to
perform discovery of Dell EMC devices.
Repair Dell EMC Alert Relay Server Installer installation errors
Steps
1. From the downloaded location, double-click the DellEMCAlertRelayServerInstaller.msi file and click Next.
2. Select Repair, and then click Next.
3. Click Install.
Results
During the repair of the Dell EMC Alert Relay Server Installer, note that:
Installation logs are not removed from the C:\Users\<admin>\AppData\Local\Temp\Dell
EMC.OMIMSSC.Configuration location.
Enrolling (registering) SCOM Management Group with OMIMSSC appliance for SCOM
33