Users Guide

Table Of Contents
Dell EMC Network Switch Power Supply Group
Dell EMC Network Switch power supply Group Health Poll Based Unit Monitor
Dell EMC Network Switch Interfaces
Dell EMC Network Switch Interfaces overall Health Unit Monitor
Event rules used by different monitoring features of
OMIMSSC
The data center administrators using the SCOM console may want to know about the rules and monitors running on a system.
The event rules that are used by different monitoring features of OMIMSSC provide information the relevant event rules
information to the administrators.
Event rules processed by the licensed (iDRAC WS-Man) monitoring
feature of OMIMSSC for PowerEdge servers and workstations
Dell Systems Event Processing Rules
OMIMSSC processes rules from Dell EMC PowerEdge Servers.
Dell EMC PowerEdge Servers through iDRACWS-Man
All informational, warning, and critical SNMP traps for Dell EMC PowerEdge Servers discovered using Dell EMC Server and Rack
Monitoring (Licensed) feature, have a corresponding SNMP trap rule. Each of these rules is processed based on the following
criteria:
Source Name = Dell Server IP
OID = Actual trap ID of the trap event
Data Provider = SNMP trap event provider
Event rules processed by the licensed (iSM-WMI) monitoring feature of
OMIMSSC for PowerEdge servers and workstations
The following section lists the rules specific to the Dell EMC Server and Rack Workstation Monitoring feature using iSM-WMI.
Dell Systems Event Processing RulesOMIMSSC processes rules from Dell EMC PowerEdge Servers.
Dell EMC PowerEdge Servers through iSM-WMIAll informational, warning, and critical events for Dell EMC PowerEdge
Servers discovered using this feature, have a corresponding event rule. Each of these rules is processed based on the
following criteria:
Source Name = Lifecycle controller Log
Event no= Actual event ID of the event
Data Provider = Windows System event log
Event rules processed by the licensed Chassis monitoring feature of
OMIMSSC
Dell Systems Event Processing RulesOMIMSSC appliance processes rules from Chassis traps.
Dell EMC Chassis devicesAll informational, warning, and critical SNMP traps for the chassis devices have a corresponding
SNMP trap rule. Each of these rules is processed based on the following criteria:
Source Name = DRAC/CMC name or IP
OID = Actual trap ID of the DRAC or CMC SNMP trap event
Data Provider = SNMP trap
NOTE:
Informational alerts are turned off by default. To receive these alerts, import informational alerts management
pack.
Reference topics 117