Users Guide

Table Of Contents
You can view the details of the warning alert in the Alert Details pane under Monitoring.
Detect and restore the status of a failed CMC or OpenManage
Enterprise-Modular
Using the iDRAC detection of a failed Dell EMC Chassis Management Controller/OpenManage Enterprise Modular (CMC/
OME- M) feature, iDRAC of a Rack Style Management (RSM) enabled modular server detects a failed or an unavailable CMC.
By using this feature, you can take immediate remedial action to bring the failed Dell EMC CMC/OME-M to a normal state.
The Dell Chassis Controller Sensor indicates the presence or failure of a Dell EMC CMC/OME-M. You can view the health state
that is obtained from the unit monitor by clicking Dell EMC Diagram Views > Dell Chassis Controller Sensor under Sensors.
NOTE:
The Dell Chassis Controller Sensor is available in both the Scalable and Detailed Management Pack editions.
iDRAC detection of failed Dell EMC CMC/OME-M is supported for YX3X and iDRAC9-based PowerEdge FX2 Chassis.
Port connection information of PowerEdge servers discovered
through iDRAC and iSM
NOTE: This feature is supported for iDRAC9-based PowerEdge servers only.
Server port connection information feature provides information about the physical mapping of switch ports to server ports,
and iDRAC dedicated port connections. This feature enables you to reduce cabling error debugging by identifying switch ports
that are connected to a servers network ports, and iDRAC dedicated port. You can view the information about the Server port
connection under iDRAC NIC and NIC objects in the Detail View pane of the Dell EMC Diagram View. Along with the inventory
information of each NIC, chassis ID information of the switch and the port ID information is populated. This feature is available
for Dell EMC PowerEdge servers that are discovered through both the iDRAC and iSM methods of Dell EMC Server and Rack
Workstation Monitoring (Licensed) feature.
Hardware components of servers and rack
workstations monitored by OMIMSSC
The following table provides information about the monitored hardware components that are supported in Scalable and Detailed
feature for Dell EMC devices that are discovered through iDRACWS-Man or iSM-WMI in OMIMSSC.
Table 18. Monitored hardware components of servers and rack workstationsScalable and Detailed
feature
Hardware
components
Server and Rack Workstation monitoring
feature using iDRAC WS-Man
Server and Rack Workstation monitoring
feature using iSM-WMI
Scalable Detailed Scalable Detailed
BIOS No No No No
Battery Sensor Group No Yes Yes Yes
Battery Sensor No Yes No Yes
Current Sensor Group No Yes No No
Current Sensor No Yes No No
Fan Sensor Group No Yes Yes Yes
Fan Sensor No Yes No Yes
Host NIC Group No Yes Yes Yes
Host NIC No Yes No Yes
Reference topics 105