Release Notes

Table 3. Known issues in OMIMSSC appliance version 7.3 for SCOM (continued)
Issue ID Functional area Description Workaround/ Resolution
NA Enrollment with
OMIMSSC appliance
OMIMSSC version
affected: 7.3
Editing the enrollment name using the Edit
option on the OMIMSSC Admin Portal is
initiating all the sub-tasks to execute.
Functionality is not impacted.
NA Discovery of devices
OMIMSSC version
affected: All
The Dell EMC PowerEdge M1000e chassis
is not getting discovered on the SCOM
console.
Upgrade the Dell EMC PowerEdge
M1000e firmware to version 6.23.
203180 Monitoring of devices
and de-enrollment with
OMIMSSC appliance
OMIMSSC version
affected: 7.2 and 7.3
The health monitoring and metrics
collection jobs created for devices
discovered in Detailed mode continue to
run even after the SCOM Management
Group is de-enrolled with the OMIMSSC
appliance.
None.
203278 Monitoring of devices
OMIMSSC version
affected: All
For devices discovered in Scalable mode,
the metrics collection tasks are created but
will remain disabled. In the Jobs and Logs
center, these tasks list under the Running
tab instead of the Scheduled tab. When
you switch back to Detailed mode and
enable the monitoring metrics, these tasks
will run as per the scheduled interval.
None.
202597 Monitoring of network
switches
OMIMSSC version
affected: 7.3
For Dell EMC Network Switches running
on OS10 firmware, the system health
status displays "Healthy" even when few
components, such as power supply and
fan, are in the "Critical" state.
Use the State view or expand the
system node in the Diagram view
to view the health status of the
components of Dell EMC Network
Switches with OS10 firmware.
Limitations
Table 4. Limitations in OMIMSSC appliance for SCOM
Functional area Limitation
Discovery and monitoring The detection of unresponsive Chassis Management Controller feature is not supported
for 13G FX2 chassis that is discovered through iDRAC Service Module (iSM) using
Windows Management Instrumentation (WMI).
Monitoring Setting preferred monitoring feature through Dell EMC Feature Management Dashboard
is not applicable to Dell EMC PowerEdge Server discovered under Dell EMC Server and
Rack Workstations (Licensed) State View using OMIMSSC.
Environment and system requirements
For more information about the hardware and software requirements of OMIMSSC version 7.3 for SCOM, see the Support
Matrix section in the Dell EMC OpenManage Integration with Microsoft System Center for System Center Operations Manager
User's Guide on www.dell.com/support.
Installation and upgrade considerations
High level deployment process of the OMIMSSC appliance:
Deploy OMIMSSC on Hyper-V or ESXi.
Log in first time as administrator using the OMIMSSC Command Line Interface (CLI).
7