Release Notes

Table 3. Known issues in OMIMSSC appliance version 7.3 for SCOM (continued)
Issue ID Functional area Description Workaround/ Resolution
OMIMSSC version
affected: All
"00:00:00:00:00:00". This issue affects the
Server and Rack Workstation Monitoring
(Licensed) feature in version 6.3 and the
out-of-band or the agent based monitoring
feature of versions 6.0 and later.
NA Discovery and inventory
OMIMSSC version
affected: All
The "Fan" components of the PowerEdge
M1000e chassis are displayed as "Dell Fan".
Upgrade the PowerEdge M1000e
firmware to 5.0.1.
NA Discovery and inventory
OMIMSSC version
affected: All (Chassis
Monitoring Feature
(Detailed), Firmware
5.0.1)
In the Chassis inventory, IP address may
not be updated for the IO module.
None.
NA Discovery and inventory
OMIMSSC version
affected: All (Chassis
Modular Server
Correlation, Server
and Rack Workstation
Monitoring, Server
and Rack Workstation
Monitoring Feature-
Licensed)
If Modular servers which are correlated to
a Chassis slot are removed from the SCOM
monitoring, the main server object may still
be visible.
None.
NA Discovery and inventory
OMIMSSC version
affected: All
When Dell EMC PowerEdge M1000e
chassis is discovered with controller
inserted in slot2 with slot1 empty, then the
value of the firmware version is displayed
as Not Applicable.
Insert the controller in slot1.
NA Discovery and
monitoring
OMIMSSC version
affected: All
The deletion of Dell EMC devices from
appliance to Operations Manager can take
a long time depending on the number of
devices that are deleted at a time.
Select few devices for deletion at a
time. Wait for few minutes after the
deletion of devices and then proceed
to delete other devices.
NA Discovery
OMIMSSC version
affected: All
If the IP addresses provided during
discovery of Dell EMC devices are
unreachable, then the discovery for those
devices runs periodically and task created
for the devices by OMIMSSC appliance
cannot be deleted.
If the provided credentials are
incorrect, then go to the Edit
Credentials Profile page to correct
them.
NA
OMIMSSC version
affected: All
After rebooting the OMIMSSC appliance,
monitoring of devices is not possible until
next discovery which is scheduled for that
particular device. Thus, updating the health
status can take up to 24 hours.
Use Configuration override page to
change only discovery override after
reboot. This will ensure discovery
is run immediately, and Health Unit
Monitors are updated in next default
cycle.
NA Discovery of devices
OMIMSSC version
affected: All
If the Dell EMC PowerEdge Servers are
discovered through sync operation in
OMIMSSC appliance and if in the next
discovery, port or credentials are changed,
discovery of such a device in Appliance will
fail in the consequent discovery cycles and
resolve sync errors page will not display
this device.
None.
4