Description: The Service Tag of a PowerVault MD 38xx Series storage array displayed in OpenManage
Essentials does not match with the Service Tag displayed in PowerVault Modular Disk Storage Manager.
[64059]
Issue 66:
Description: If the mode of the IOAs in a chassis is changed from Standalone or VLT to PMUX, the IOAs
of a chassis are not discovered when using the Chassis (CMC) Discovery — All Components filter.
[65026]
Resolution: Do one of the following:
• Update the SNMP Community string of the IOA in the corresponding CMC console.
• Discover the IOAs separately in OpenManage Essentials.
Issue 67:
Description: The Memory Type information is displayed as Unknown in the device inventory, when a
server running VMware ESXi and with DDR4 type memory DIMM is discovered by using the operating
system IP address (in-band) with WS-MAN protocol.
Resolution: Discover the server by using the iDRAC IP address (out-of-band) with WS-Man protocol.
Alerts
OpenManage Essentials can receive and process alerts from systems with an IPv4 address format.
Issue 1:
Description: Some of the alerts received in OpenManage Essentials from Dell Networking C-Series
devices may not indicate the actual cause of error or problem on the device.
Issue 2:
Description: OpenManage Essentials may receive alerts with unknown severity from SonicWALL firewall
devices. [41420]
Resolution: To change the severity of the alert, edit the alert/trap definition using the MIB Import Utility.
Issue 3:
Description: FluidFS alerts received from the controller or management member IP are not associated
with the corresponding Dell EqualLogic FS7500 NAS device. [39667]
Issue 4:
Description: If the intensity of an alert storm increases beyond 5 traps per second, it could take
OpenManage Essentials several minutes to process all the alerts. New alerts that are received in the
interim are not displayed on the console until all the alerts in the storm are processed.
Issue 5:
22