Release Notes

If the cluster IP address is the only IP address in the discovery task that is related to the HA Cluster, the
currently active cluster node will be discovered and its name will be the same as that of the cluster itself.
This results in the cluster name appearing in several places under the All Devices organizational view.
Another option which helps with cluster discovery is setting the name resolution to NetBIOS instead of
DNS names and running the discovery.
Issue 50:
Description: For Dell’s 13th Generation of PowerEdge servers discovered using out-of-band method, the
system uptime displayed in OpenManage Essentials may not match with the actual system uptime.
[51626]
Issue 51:
Description: OpenManage Essentials may not display the appropriate version in the inventory for
OpenManage Storage Servcies (OMSS) version 8.0.2. [51149]
Issue 52:
Description: After replacing a server (source) with another server (target) from a compute pool, if the
operating system IP address is discovered again, drill-down of the IP address on the Discovery and
Inventory page displays both the source and target servers. [61513]
Resolution: Delete both the servers and then discover the servers again.
Issue 53:
Description: In OpenManage Essentials version 2.2, when the iDRAC and the server with the iDRAC are
correlated:
Deleting the discovery range of the iDRAC removes the iDRAC details in the NIC Information table of
the server. However, the iDRAC is not removed from the device tree.
Deleting the discovery range of the server removes the server details in the NIC Information table of
the iDRAC. However, the server is not removed from the device tree. [61985]
Issue 54:
Description: For EqualLogic PS4210 storage arrays with EqualLogic firmware version 8.0.4, the
Application Launch option is disabled. [62421]
Issue 55:
Description: When a server is discovered with the SNMP protocol, the RAC name of the server is not
displayed in the device tree, portals, and wizards. [64443]
Resolution: Ensure that the iDRAC of the server is discovered with the WS-Man protocol. Otherwise, the
system name is displayed in the device tree, portals, and wizards instead of the RAC name.
Issue 56:
Description: The location of a server is not displayed in the Device Summary table when the server is
discovered out-of-band with either the WS-Man or SNMP protocol. [62819]
20