Release Notes
Table Of Contents
Description: OpenManage Essentials launches in Internet Explorer even if any other browser is set as the
default browser. [35491]
Issue 3:
Description: OpenManage Essentials does not launch or displays an exception when the number of
connections to the OpenManage Essentials website is limited in IIS.
Resolution: The OpenManage Essentials console requires constant communication with the web server
to ensure that the data is up-to-date always. The communication between the console and the web
server is performed utilizing web method calls in a multi-threaded environment. As such, multiple,
simultaneous connections to the web server are required in order for OpenManage Essentials to operate
properly. As a general rule, ensure that your web server is configured for a minimum of 50 active
connections.
Issue 4:
Description: When launching OpenManage Essentials, the following error is displayed:
Client Logon credentials not authorized error. [31507]
Resolution: Restart the DSM Essentials Host service.
Issue 5:
Description: OpenManage Essentials does not launch when the IP address of the remote database is
changed. [31801]
Resolution: Reinstall OpenManage Essentials and target the existing remote database with the new IP
address.
Discovery and Inventory
The processor count in OpenManage Essentials differs for managed systems that contain processors with
multiple cores or HyperThreading enabled. The count differs based on whether the managed system is
discovered using the CIM or SNMP protocol. The systems discovered using SNMP report physical
processors, and the systems discovered using CIM report logical processors.
Issue 1:
Description: In the OpenManage Essentials GUI, if you attempt to create a discovery range with an IP
address ending in .0, the following error message is displayed: The last octet cannot be 0.
Depending on the subnet mask, an IP address ending in
.0 is valid for a device. [48781]
To workaround this issue, import a .csv file with a device IP ending in .0. OpenManage Essentials
discovers and classifies the device properly using this method.
Issue 2:
Description: If you create a new custom device group with modular servers, and perform another
discovery, all the server objects in that group are lost. [49224]
12