Release Notes

Configuration Management
Issue 1:
Description
When the Deploy Template wizard is run and both deployment and boot-to-network-ISO are requested,
if the boot-to-network-ISO task fails to start for some reason, the task will never show that it has
completed. The task details window shows the failure and the task completes, but it fails to update its
status in the database, so the UI never shows it as completed. [52861]
Resolution
If the task details contains a message that the boot-to-network-ISO task failed to start, and the task
continues to show as running, manually stop the task using the context menu on the task. The task has
already ended, but stopping it manually will update the database so the task doesn't appear to be still
running.
Issue 2:
Description
The device configuration Inventory and Compliance tabs in the Devices Portal display inventory and
compliance information only after the corresponding tab is manually refreshed. [48567]
Issue 3:
Description
For device configuration inventory tasks, the Task Execution History displays the user who ran the task as
System. [48738]
Issue 4:
Description
If a device on which a configuration template was deployed, is deleted and then rediscovered, the last
template deployed on the device is not displayed in the “Repurpose and Bare Metal Devices” tab.
Issue 5:
Description:
Auto deployment tasks created in OpenManage Essentials version 2.0 do not run successfully after
upgrade to version 2.0.1 or version 2.1.[61955]
Resolution:
Recreate the auto deployment task after the upgrade.
Security
To prevent security issues due to cross frame scripting (XFS) in Internet Explorer, you must disable web
frames across different domains:
1. Click Tools Internet Options.
2. Click Security.
3. Under Select a zone to view or change security settings, select Local intranet.
4. Under Security level for this zone, click Custom level.
5. Under Miscellaneous Navigate windows and frames across domains, select either Prompt or
Disable.
Reports
Issue 1:
Description
In the Agent and Alert Summary report, if the devices are filtered by any Group other than “All Devices”,
the Agent Summary table does not display the correct information. [49510]