Release Notes

Issue 40:
Description
Discovery and inventory of servers that have virtual network adapters are not displayed in the “NIC
Information” table of the server. This occurs when discovering and inventorying Microsoft Windows
servers with SNMP, WMI, or both along with Hyper-V role configured with virtual networks adapters.
Resolution:
OME displays only the IP of the network adapter it was discovered on. If it is a virtual network adapter, it
displays “Host NIC Adapter”. OME displays only the physical network adapters in theNIC Information”
table of the server.
Issue 41:
Description
When discovering and inventorying Dell 12G servers using SNMP, there may be some instances where
the device is removed from the device tree and replaced with another 12G server. This issue is known to
occur with the initial release of the iDRAC7 firmware 1.06.06.
Resolution:
It is recommended that the iDRAC7 firmware is updated to version 1.20.20 or later.
Issue 42:
Description
If you import more than 1,500 discovery ranges (each range can have one or more IP addresses) using
the Discovery “import CSV” feature, the first time you navigate to the “Manage | Discovery and
Inventory“ page, you may see a delay of 10-15 seconds until the page loads. After that, subsequent visits
to that page will load normally.
Resolution:
Do one of the following:
Allow the console to complete loading for up to 15 seconds.
Do not import individual IP addresses, instead import the IP ranges.
Issue 43:
Description
While discovering ESXi 5.0 and ESXi 5.0 U1 using WSMAN you may observe that the discovery task may
take about 6 minutes. This issue is due to the enhanced information OME is gathering from the ESXi 5
host and the increased storage and software calls being sent to the OMSA ESXi 5 VIB.
Resolution:
Do one of the following:
Perform discovery and inventory of ESXi 5 when the servers are not busy.
Review the Performance and Scalabilitywhite paper at delltechcenter.com/ome for other
recommendations.