Release Notes

Issue 49:
Description
HA Clusters can be discovered using SNMP only. The discovery task that is intended to discover HA
Clusters must have SNMP enabled and the associated credentials must be correct for the target devices.
In order for the members to be discovered, the IP address of each cluster member must be included in
the list of addresses to be discovered by the discovery task.
When discovering HA Clusters, the cluster name may replace the name of the active cluster node. To
avoid this, do not include the cluster IP address in the discovery range.
If the cluster IP address is the only IP address in the discovery task that is related to the HA Cluster, the
currently active cluster node will be discovered and its name will be the same as that of the cluster itself.
This results in the cluster name appearing in several places under the All Devices organizational view.
Another option which helps with cluster discovery is setting the name resolution to NetBIOS instead of
DNS names and running the discovery.
Issue 50:
Description
For Dell’s 13th Generation of PowerEdge servers discovered using out-of-band method, the system
uptime displayed in OpenManage Essentials may not match with the actual system uptime. [51626]
Issue 51:
Description
OpenManage Essentials may not display the appropriate version in the inventory for OpenManage
Storage Servcies (OMSS) version 8.0.2. [51149]
Alerts
OpenManage Essentials can receive and process alerts from systems with an IPv4 address format.
Issue 1:
Description
Some of the alerts received in OpenManage Essentials from Dell Networking C-Series devices may not
indicate the actual cause of error or problem on the device.
Issue 2:
Description
OpenManage Essentials may receive alerts with unknown severity from SonicWALL firewall devices.
[41420]
Resolution
To change the severity of the alert, edit the alert/trap definition using the MIB Import Utility.
Issue 3:
Description
FluidFS alerts received from the controller or management member IP are not associated with the
corresponding Dell EqualLogic FS7500 NAS device. [39667]
Issue 4:
Description
If the intensity of an alert storm increases beyond 5 traps per second, it could take OpenManage
Essentials several minutes to process all the alerts. New alerts that are received in the interim are not
displayed on the console until all the alerts in the storm are processed.