User's Manual

3. After you have provided at least one IP address, IP range, host name, or a combination thereof,
continue to customize the discovery and inventory options or complete the configuration using the
default options. Clicking Finish without setting any further configurations immediately runs the
discovery and inventory tasks using the default SNMP and ICMP protocols. It is recommended that
you review and revise your protocol configurations prior to clicking
Finish.
For more information about each protocol listed below, click - (Why do I need this?) help in the
appropriate protocol configuration screen.
NOTE: When discovering ESXi-based servers, to view the guest virtual machines grouped with
the host, enable and configure the WS-Man protocol.
NOTE: By default, SNMP is enabled and values are assigned ICMP parameters.
NOTE: After completing any of the following steps, click either Next to continue or click Finish
to complete the Discovery Range Configuration.
In ICMP Configuration, to detect devices on the network, edit the ICMP parameters.
In SNMP Configuration, to discover servers, provide the SNMP parameters. Ensure that the SNMP
community string specified in Get Community matches the SNMP community string of the
device or devices you wish to discover.
NOTE: iDRAC only supports only the default SNMP port 161. If the default SNMP port is
changed, iDRAC may not get discovered.
In WMI Configuration, to authenticate and connect to remote devices, provide the WMI
parameters. The format for entering credentials for WMI must be
domain\user name for domain-
based networks or localhost\user name for non-domain based networks.
In Storage Configuration, to discover PowerVault modular disk array or EMC devices, edit
parameters.
In WS-Man Configuration, to enable discovery of Dell PowerEdge VRTX, iDRAC 6, iDRAC 7, and
ESXi installed servers, provide WS-Man parameters.
In SSH Configuration, to enable discovery of Linux-based servers, provide the SSH parameters.
In IPMI Configuration, to enable server discovery, provide the IPMI parameters. IPMI is typically
used to discover BMC or iDRACs on Dell servers. You can include the optional KG key when
discovering RAC devices.
In Discovery Range Action, choose to discover, inventory, or perform both tasks. The default
option is to perform both discovery and inventory.
Select Perform only discovery or Perform both discovery and inventory to run the task
immediately.
To schedule the task to run at a later time, select Do not perform discovery or inventory, and
follow the instructions in Scheduling Discovery and Scheduling Inventory.
Review your selections in the Summary screen and click Finish. To change any of the parameters
in previous configuration screens, click Back. When complete, click Finish.
Related Links
Discovery and Inventory Portal
Last Discovery and Inventory
Discovered Versus Inventoried Devices
Task Status
Changing the Default SNMP Port
SNMP uses the default UDP port 161 for general SNMP messages and UDP port 162 for SNMP trap
messages. If these ports are being used by another protocol or service, you can change the settings by
58