Owner's Manual
Issue 4:
Description
When a PowerEdge FX2s chassis is discovered using WS-Man protocol, the host name of the
corresponding mapped sled is not displayed in the PCIe Slot Information table in the device
inventory. [37351]
Issue 5:
Description
When a PowerEdge FM120x4 sled is discovered in-band using SSH protocol, the Embedded Device
Information table is not displayed in the device inventory. [39312]
Issue 6:
Description
When a PowerEdge FM120x4 sled is discovered using SNMP+WMI protocol, the Software Inventory Table
displays multiple entries for the iDRAC version. [39428]
Issue 7:
Description
If a device is not configured with the system contact details, the "Contact Information" table is not
displayed in the device inventory information. [36733]
Issue 8:
Description
If the PowerEdge RAID Controllers (PERC) in a PowerEdge VRTX chassis have different versions of
firmware installed, the "Software Inventory Information" table displays only the PERC with the main
controller firmware version. [39761]
Resolution
Make sure you update the firmware version of the PERC manually in the Chassis Management Controller
console.
Issue 9:
Description
Dell EqualLogic FS7500 NAS device discovered using the management or member IP is displayed as
Unknown in the device tree. [39618]
Resolution
Discover the Dell EqualLogic FS7500 NAS device using the group manager IP.
Issue 10:
Description
If a Dell PowerEdge VRTX chassis is discovered using SNMP protocol and NetBIOS name resolution
setting, the instrumentation (NetBIOS) name is not resolved. [27327]
Issue 11:
Description
When a monolithic Dell 11th or 12th Generation PowerEdge server with iDRAC6/7 is discovered using the
IPMI protocol only (iDRAC out-of-band discovery), the overall health status of the server is not reported
correctly in OpenManage Essentials. This issue occurs due to a known limitation in iDRAC. [21599]
Resolution: