Connectivity Guide

drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined in the Dell Remote Access Controller Out-of-
Band Group section.
System Trap Group
The System Trap Group contains traps that fall under the System event category.
Table 285. Amperage Probe Traps
TrapID Description Category SubCategory Severity
alert2AmperageProbeNormal
2179 Current sensor reading is within
range.
Status Events Amperage Informational
alert2AmperageProbeWarning
2178 Current sensor has detected a
warning value.
Status Events Amperage Minor
alert2AmperageProbeFailure
2177 Current sensor has detected a
failure value.
Error Events Amperage Critical
Table 286. Battery Traps
TrapID Description Category SubCategory Severity
alert2BatteryNormal
2227 Battery state has returned to
normal; or battery presence had
been detected.
Status Events Battery Informational
alert2BatteryWarning
2226 Battery is low. Status Events Battery Minor
alert2BatteryFailure
2225 Battery has failed or battery is
absent.
Error Events Battery Critical
Table 287. Cable Traps
TrapID Description Category SubCategory Severity
alert2CableFailure
2393 Cable failure. Error Events Cable Critical
Table 288. CMC Traps
TrapID Description Category SubCategory Severity
alert2CMCWarning
2546 Chassis Management Controller
detected a warning.
Status Events CMC Minor
alert2CMCFailure
2545 Chassis Management Controller
detected an error.
Error Events CMC Critical
66 SNMP Traps