Connectivity Guide
Table 283. BMC Traps (continued)
TrapID Description Severity
789248 Memory redundancy has returned to
Normal
Information
1076994 System Event Log (SEL) Cleared Information
1076996 System Event Log (SEL) Full (Logging
Disabled)
Critical
2322176 ASR (Automatic System Recovery)
Timer Expired
Critical
2322177 ASR (Automatic System Recovery)
Reset Occurred
Critical
2322178 ASR (Automatic System Recovery)
Power Down Occurred
Critical
2322179 ASR (Automatic System Recovery)
Power Cycle Occurred
Critical
PowerEdge M1000e CMC Traps
This section describes the traps that are generated by the SNMP agent of the PowerEdge M1000e CMC. All of the enterprise-
specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with
the following trap variables: drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem,
drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage.
PowerEdge M1000e CMC version 5.0 and later supports a setting to generate the traps listed in the section "PowerEdge VRTX
CMC Traps and PowerEdge FX2 CMC Traps". The setting is named "Enable Enhanced Chassis Logging and Events" in the
PowerEdge M1000e CMC GUI and is located in the General Chassis Settings page which can be found by navigating to Chassis
Overview -> Setup -> General in the CMC GUI. When the setting is disabled, the traps listed in this section are generated by the
CMC. When the setting is enabled, the traps listed in the section "PowerEdge VRTX CMC Traps and PowerEdge FX2 CMC
Traps" are generated by the CMC instead of the traps listed in this section. The setting is disabled by default. The trap variables
are defined in the Dell Remote Access Controller Out-of-Band Group section.
Table 284. PowerEdge M1000e CMC traps
TrapID Name Description Severity Category
2000 alertCMCTestTrap CMC has generated a test
trap.
Informational Error Events
2002 alertCMCNormalTrap CMC reported a return-to-
normal or informational event.
Normal Error Events
2003 alertCMCWarningTrap CMC reported a warning
event.
Warning Error Events
2004 alertCMCCriticalTrap CMC reported a critical event. Critical Error Events
2005 alertCMCNonRecoverable
Trap
CMC reported a catastrophic
event.
Non-Recoverable Error Events
PowerEdge VRTX CMC 3.3 , PowerEdge FX2 CMC 2.3
and OM Enterprise Modular Traps 1.20.00
This section defines the traps that are generated by the SNMP agent of the PowerEdge VRTX CMC , PowerEdge FX2 CMC and
OM Enterprise Modular. All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by
OID 1.3.6.1.4.1.674.10892.2.21 and OID 1.3.6.1.4.1.674.10892.6.5.0 , are sent with the following trap variables: drsCA2MessageID,
drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation,
SNMP Traps