Connectivity Guide

Table 257. DmmPSUTable (continued)
Object ID 1.3.6.1.4.1.674.10892.6.1.4.2
Description This object defines the PSU table.
Syntax SEQUENCE OF DmmPSUTableEntry
Access Read-only
Table 258. DmmPSUTableEntry
Name
dmmPSUTableEntry
Object ID 1.3.6.1.4.1.674.10892.6.1.4.2.1
Description This object defines the PSU table entry.
Syntax DmmPSUTableEntry
Access Read-only
Power Information
The following MIB attributes provide power information for the Enterprise - Modular Management
Table 259. DmmPowerChassisIndex
Name
dmmPowerChassisIndex
Object ID 1.3.6.1.4.1.674.10892.6.4.1.1.1
Description This attribute defines the index (one-based) of the associated chassis .
Syntax DellPowerIndexRange
Access Read-only
Table 260. DmmPowerIdlePower
Name
dmmPowerIdlePower
Object ID 1.3.6.1.4.1.674.10892.6.4.1.1.2
Description This attribute defines the power (in Watts) required by the chassis infrastructure, plus
the sum of the minimum power requirements for all currently powered-on servers.
Syntax DellPowerReading
Access Read-only
Table 261. DmmPowerKWhCumulative
Name
dmmPowerKWhCumulative
Object ID 1.3.6.1.4.1.674.10892.6.4.1.1.3
Description This attribute defines the cumulative chassis power usage (in KWh) since last reset.
Syntax DellPowerReading
Access Read-only
Table 262. DmmPowerKWhCumulativeTime
Name
dmmPowerKWhCumulativeTime
Object ID 1.3.6.1.4.1.674.10892.6.4.1.1.4
56 OpenManage Enterprise-Modular Management Software Group